ModelStorageTek 9985V
ManufacturerSun Microsystems Inc
Array TypeFC
Product IdHITACHI
Vendor IdOPEN
Storage Virtual ApplianceNo

Notes:

  • For further details about array firmware, storage product configurations and best practices, please contact the storage vendor
ReleaseModePath PolicyFirmwareDevice Driver(s)Configuration
ESX 4.0 U1 VMW_SATP_DEFAULT_AAVMW_PSP_FIXED60-04-06-00/02lpfc820 version 8.2.0.30.49vmw, qla2xxx version 821.k1.38vmwFC Switched
ESX 4.0 U1 VMW_SATP_DEFAULT_AAVMW_PSP_FIXED60-04-06-00/02qla2xxx version 821.k1.38vmw, lpfc820 version 8.2.0.30.49vmwFC Direct Attached
ESX 4.0 VMW_SATP_DEFAULT_AAVMW_PSP_FIXED60-04-06-00/02qla2xxx version 821.k1.38vmw, lpfc820 version 8.2.0.30.49vmwFC Switched
ESX 4.0 VMW_SATP_DEFAULT_AAVMW_PSP_FIXED60-04-06-00/02lpfc820 version 8.2.0.30.49vmw, qla2xxx version 821.k1.38vmwFC Direct Attached
ESX 3.5 U4 Active/ActiveFixed60-02-25-00/00N/AFC Switched
ESX 3.5 U4 N/AN/A60-02-26-00-0N/AFC Switched
ESX 3.5 U31 N/AN/A60-02-26-00-0N/AFC Switched
ESX 3.5 U3 Active/ActiveFixed60-02-25-00/00lpfc_740 version elx_7.4.0.13, qla2300_707_vmw version 7.08-vm32FC Switched
ESX 3.5 U21 N/AN/A60-02-26-00-0N/AFC Switched
ESX 3.5 U2 Active/ActiveFixed60-02-25-00/00qla2300_707_vmw version 7.08-vm32, lpfc_740 version elx_7.4.0.13FC Switched
ESX 3.5 U1 Active/ActiveFixed60-02-25-00/00qla2300_707_vmw version 7.08-vm32, lpfc_740 version elx_7.4.0.13FC Switched
ESX 3.5 Active/ActiveFixed60-02-25-00/00lpfc_740 version elx_7.4.0.13, qla2300_707_vmw version 7.08-vm32FC Switched
ESX 3.0.32, 3 kb: 1 Active/ActiveFixed60-02-25-00/00qla2x00_707 version 7.07.04.01.3vmw, lpfcdd_732 version 7.3.2_vmw10FC Switched
ESX 3.0.2 U12, 3 kb: 1 Active/ActiveFixed60-02-25-00/00qla2x00_707 version 7.07.04.2vmw, lpfcdd_732 version 7.3.2_vmw4FC Switched
ESX 3.0.22, 3 kb: 1 Active/ActiveFixed60-02-25-00/00qla2x00_707 version 7.07.04.2vmw, lpfcdd_732 version 7.3.2_vmw4FC Switched
ESX 3.0.14 Active/ActiveFixed60-02-25-00/00lpfcdd_732 version 7.3.2_vmw2, qla2x00_707 version 7.07.04.01FC Switched
ESX 3.04, 5 Active/ActiveFixed60-02-25-00/00N/AFC Switched

Notes:

  • Storage partners using ESX 4.0 or later may recommend VMW_PSP_RR for path failover policy for certain storage array models. If desired, contact the storage array manufacturer for recommedation and instruction to set VMW_PSP_RR appropriately.

  • 1. Supported with Brocade 8Gb FC bfa 1.0.0.02 driver
  • 2. MSCS supported with both 2Gb and 4Gb Fibre Channel HBAs on ESX Server 3.0.2 or later.
  • 3. MSCS supported with Windows Server 2003 SP1 Enterprise Edition, Windows Server 2003 SP2 Enterprise Edition and Windows Server 2003 R2 Enterprise Edition.
  • 4. Limited to internal storage configurations only.
  • 5. Supported with Qlogic 7.07.04 and Emulex 7.3.2_vmw2 drivers or later versions

KB Articles:

THIS CONTENT IS PROVIDED AS IS, AND TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, VMWARE DISCLAIMS ALL OTHER REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED, REGARDING THIS CONTENT, INCLUDING THEIR FITNESS FOR A PARTICULAR PURPOSE, THEIR MERCHANTABILITY, OR THEIR NONINFRINGEMENT. VMWARE SHALL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OF THIS CONTENT, INCLUDING DIRECT, INDIRECT, CONSEQUENTIAL DAMAGES, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF VMWARE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

THE VMWARE COMPATIBILITY GUIDE IS UPDATED FROM TIME TO TIME WITHOUT NOTICE. FOR THE LATEST VMWARE COMPATIBILITY GUIDE, PLEASE GO TO THE FOLLOWING LINK: http://www.vmware.com/resources/compatibility