title: VMmark 3.x Results
url: https://www.vmware.com/resources/vmmark/results3x
description: VMmark results have been submitted to a review panel composed of a variety of companies that have published VMmark benchmark results, ensuring the fairness and integrity of the benchmark. VMmark has become the standard by which the performance of virtualization platforms is evaluated.
---

# VMmark 3.x Results

## [New VMmark Results Featuring 4th Gen Intel® Xeon® Scalable Processors and vSphere 8](https://blogs.vmware.com/performance/2023/01/new-vmmark-results-featuring-4th-gen-intel-xeon-scalable-processors-and-vsphere-8.html)

**Date:** 2023-01-10

### [New VMmark Results Feature vSphere 8 and 4th Gen AMD EPYC™ Processors](https://blogs.vmware.com/performance/2022/11/new-vmmark-results-featuring-vsphere-8-and-4th-gen-amd-epyc-processors.html)

**Date:** 2022-11-17

### [Updated VMmark User's Guide with New Quick Start Section](https://communities.vmware.com/t5/VMware-VMmark-Discussions/Updated-VMmark-User-s-Guide/m-p/2861987)

**Date:** 2021-08-19

**Top Scores - 1 Socket Servers**

- **20.65** - Dell PowerEdge R7615
- **13.51** - Dell PowerEdge R7615
- **12.06** - Dell EMC PowerEdge R7515

[VIEW ALL](https://www.vmware.com/resources/vmmark/results3x?matched_pair[]=Matched%20Pair&sort=score&sortorder=sorting_dsc&total_sockets[]=2#performance-only)

**Recently Published vSAN Storage**

| Score  | Description                                 | Date       |
|--------|---------------------------------------------|------------|
| 52.75  | IEIT Systems Co. Ltd inMerge1100M7S         | 07/09/2024 |
| 51.94  | IEIT Systems Co. Ltd inMerge1100M7S         | 06/11/2024 |
| 12.18  | Supermicro SYS-111C-NR                      | 05/14/2024 |

[VIEW ALL](https://www.vmware.com/resources/vmmark/results3x?sort=date&sortorder=sorting_dsc&type_of_storage[]=vSAN%20Storage#performance-only)

**Top Overall Score**

- **63.01** - Dell EMC PowerEdge R6525
- **52.75** - IEIT Systems Co. Ltd inMerge1100M7S
- **51.94** - IEIT Systems Co. Ltd inMerge1100M7S

[VIEW ALL](https://www.vmware.com/resources/vmmark/results3x?sort=score&sortorder=sorting_dsc#performance-only)

**Top Scores - 2 Socket Servers**

- **47.78** - Supermicro AS-2125HS-TNR
- **45.59** - Fujitsu Server PRIMERGY RX2450 M2
- **44.15** - Dell PowerEdge R7625

[VIEW ALL](https://www.vmware.com/resources/vmmark/results3x?matched_pair[]=Matched%20Pair&sort=score&sortorder=sorting_dsc&total_sockets[]=4#performance-only)

**Recently Published**

| Score  | Description                                 | Date       |
|--------|---------------------------------------------|------------|
| 52.75  | IEIT Systems Co. Ltd inMerge1100M7S         | 07/09/2024 |
| 51.94  | IEIT Systems Co. Ltd inMerge1100M7S         | 06/11/2024 |
| 12.18  | Supermicro SYS-111C-NR                      | 05/14/2024 |

[VIEW ALL](https://www.vmware.com/resources/vmmark/results3x?sort=date&sortorder=sorting_dsc#performance-only)

**Top Scores - Server Power-Performance**

- **21.02 PPKW** - Dell PowerEdge R7615
- **18.20 PPKW** - Dell PowerEdge C6615
- **14.25 PPKW** - Fujitsu Server PRIMERGY RX2450 M2

[VIEW ALL](https://www.vmware.com/resources/vmmark/results3x?sort=score&sortorder=sorting_dsc#server-power-performance)

**Top Scores - 4 Socket Servers**

- **45.06** - HPE ProLiant DL560 Gen11
- **44.69** - Fujitsu Server PRIMERGY RX4770 M7
- **44.51** - HPE ProLiant DL560 Gen11

[VIEW ALL](https://www.vmware.com/resources/vmmark/results3x?matched_pair[]=Matched%20Pair&sort=score&sortorder=sorting_dsc&total_sockets[]=8#performance-only)

**Top Scores - 8 Socket Servers**

- **33.04** - Fujitsu Server PRIMEQUEST 3800E2

[VIEW ALL](https://www.vmware.com/resources/vmmark/results3x?matched_pair[]=Matched%20Pair&sort=score&sortorder=sorting_dsc&total_sockets[]=16#performance-only)

**Top Scores - Server and Storage Power-Performance**

- **39.11 PPKW** - Dell PowerEdge R760
- **11.06 PPKW** - Dell PowerEdge C6615
- **7.49 PPKW** - Dell PowerEdge R7615

[VIEW ALL](https://www.vmware.com/resources/vmmark/results3x?sort=score&sortorder=sorting_dsc#server-and-storage-power-performance)

- Submitter
- Dell EMC
- Dell Technologies
- Fujitsu
- Hewlett Packard Enterprise
- Hitachi Vantara
- Huawei
- IEIT SYSTEMS Co. Ltd
- Inspur
- Lenovo
- Quanta Cloud Technology
- Sirius Computer Solutions
- StorageReview.com
- Sugon
- Supermicro
- World Wide Technology
- xFusion Digital Technologies Co. Ltd

- Total Hosts
- 2
- 3
- 4
- 6
- 8
- 16
- 24

- Total Sockets
- 2
- 3
- 4
- 6
- 8
- 12
- 16
- 32
- 48

- Total Cores
- 16
- 18
- 64
- 88
- 112
- 128
- 144
- 160
- 176
- 192
- 208
- 224
- 240
- 256
- 288
- 320
- 384
- 416
- 448
- 480
- 512
- 576
- 864
- 1024

- Server Description
- Dell EMC PowerEdge C6525
- Dell EMC PowerEdge R740xd
- Dell EMC PowerEdge R750
- Dell EMC PowerEdge R940
- Dell EMC PowerEdge R6525
- Dell EMC PowerEdge R7515
- Dell EMC PowerEdge R7525
- Dell PowerEdge C6615
- Dell PowerEdge R760
- Dell PowerEdge R860
- Dell PowerEdge R7525
- Dell PowerEdge R7615
- Dell PowerEdge R7625
- Dell PowerEdge T550
- Fujitsu Server PRIMEQUEST 3800E
- Fujitsu Server PRIMEQUEST 3800E2
- Fujitsu Server PRIMERGY CX2560 M4
- Fujitsu Server PRIMERGY CX2560 M5
- Fujitsu Server PRIMERGY CX2560 M6
- Fujitsu Server PRIMERGY RX1330 M4
- Fujitsu Server PRIMERGY RX1330 M5
- Fujitsu Server PRIMERGY RX2450 M1
- Fujitsu Server PRIMERGY RX2450 M2
- Fujitsu Server PRIMERGY RX2540 M4
- Fujitsu Server PRIMERGY RX2540 M5
- Fujitsu Server PRIMERGY RX2540 M6
- Fujitsu Server PRIMERGY RX2540 M7
- Fujitsu Server PRIMERGY RX4770 M4
- Fujitsu Server PRIMERGY RX4770 M5
- Fujitsu Server PRIMERGY RX4770 M6
- Fujitsu Server PRIMERGY RX4770 M7
- Hitachi Unified Compute Platform HC V124N
- HPE ProLiant DL320 Gen11
- HPE ProLiant DL325 Gen10
- HPE ProLiant DL345 Gen10 Plus
- HPE ProLiant DL345 Gen11
- HPE ProLiant DL380 Gen9
- HPE ProLiant DL380 Gen10
- HPE ProLiant DL380 Gen10 (Submitted by World Wide Technology)
- HPE ProLiant DL380 Gen10 Plus
- HPE ProLiant DL380 Gen11
- HPE ProLiant DL385 Gen10
- HPE ProLiant DL385 Gen10 Plus v2
- HPE ProLiant DL385 Gen11
- HPE ProLiant DL560 Gen11
- HPE ProLiant DL580 Gen10
- HPE Superdome Flex 280
- HPE Synergy 480 Gen10
- Huawei FusionServer 2288H V5
- Huawei FusionServer 2288H V6
- IEIT Systems Co. Ltd inMerge1100M7S
- Inspur InMerge1100 (Inspur NF5280M6)
- Lenovo ThinkSystem SR655
- Lenovo ThinkSystem SR665
- Lenovo ThinkSystem SR665 V3
- Quanta Cloud Technology QuantaPlex T42S-2U
- QuantaGrid D52B-1U
- QuantaPlex T42S-2U
- Sugon I620-G30
- Supermicro AS-1115CS-TNR
- Supermicro AS-2125HS-TNR
- Supermicro SuperServer SYS-220BT-DNTR
- Supermicro SuperServer SYS-220BT-HNTR
- Supermicro SuperServer SYS-2029BT-HNC0R
- Supermicro Superserver SYS-2029BT-HNR
- Supermicro SYS-111C-NR
- Supermicro SYS-221BT-DNTR
- Supermicro SYS-221H-TNR
- Supermicro SYS-1029U-TN10RT
- xFusion Digital Technologies Co. Ltd 2288H V5
- xFusion Digital Technologies Co. Ltd 2288H V6
- xFusion Digital Technologies Co. Ltd 2288H V7
- xFusion Digital Technologies Co. Ltd 2488H V6

- Processor Model
- AMD EPYC 7F72
- AMD EPYC 7H12
- AMD EPYC 72F3
- AMD EPYC 73F3
- AMD EPYC 74F3
- AMD EPYC 75F3
- AMD EPYC 7702
- AMD EPYC 7702P
- AMD EPYC 7713
- AMD EPYC 7742
- AMD EPYC 7763
- AMD EPYC 7773X
- AMD EPYC 8534P
- AMD EPYC 9174F
- AMD EPYC 9374F
- AMD EPYC 9454
- AMD EPYC 9474F
- AMD EPYC 9554
- AMD EPYC 9554P
- AMD EPYC 9654
- AMD EPYC 9654P
- AMD EPYC 9684X
- AMD EPYC 9754
- Intel Xeon E5-2699A v4
- Intel Xeon E-2186G
- Intel Xeon E-2288G
- Intel Xeon E-2388G
- Intel Xeon Gold 5120
- Intel Xeon Gold 5220
- Intel Xeon Gold 5318Y
- Intel Xeon Gold 6130
- Intel Xeon Gold 6140
- Intel Xeon Gold 6142
- Intel Xeon Gold 6152
- Intel Xeon Gold 6226R
- Intel Xeon Gold 6230
- Intel Xeon Gold 6240
- Intel Xeon Gold 6252
- Intel Xeon Gold 6338
- Intel Xeon Gold 6354
- Intel Xeon Gold 6448Y
- Intel Xeon Gold 6454S
- Intel Xeon Gold 6548Y+
- Intel Xeon Platinum 8164
- Intel Xeon Platinum 8180
- Intel Xeon Platinum 8180M
- Intel Xeon Platinum 8268
- Intel Xeon Platinum 8276L
- Intel Xeon Platinum 8280
- Intel Xeon Platinum 8352Y
- Intel Xeon Platinum 8380
- Intel Xeon Platinum 8380H
- Intel Xeon Platinum 8380HL
- Intel Xeon Platinum 8454H
- Intel Xeon Platinum 8470
- Intel Xeon Platinum 8480+
- Intel Xeon Platinum 8490H
- Intel Xeon Platinum 8592+

- Type of Storage
- Traditional Storage
- vSAN Storage

- Hypervisor
- VMware ESXi 6.5
- VMware ESXi 6.5 Patch 02
- VMware ESXi 6.5 Patch 2
- VMware ESXi 6.5 U1
- VMware ESXi 6.5 U1g
- VMware ESXi 6.5 U2
- VMware ESXi 6.5.0a
- VMware ESXi 6.5.0d
- VMware ESXi 6.7
- VMware ESXi 6.7 + AMD EPYC™ 7002 Series support
- VMware ESXi 6.7 EP 02a
- VMware ESXi 6.7 EP 03
- VMware ESXi 6.7 EP 05
- VMware ESXi 6.7 EP 06
- VMware ESXi 6.7 EP 08
- VMware ESXi 6.7 EP 15
- VMware ESXi 6.7 P01
- VMware ESXi 6.7 P04
- VMware ESXi 6.7 U3
- VMware ESXi 7.0
- VMware ESXi 7.0 U1
- VMware ESXi 7.0 U2
- VMware ESXi 7.0 U2a
- VMware ESXi 7.0 U3
- VMware ESXi 7.0 U3c
- VMware ESXi 7.0 U3d
- VMware ESXi 8.0 GA
- VMware ESXi 8.0 U1
- VMware ESXi 8.0 U1a
- VMware ESXi 8.0 U2
- VMware ESXi 8.0a
- VMware ESXi 8.0b

- vCenter Server
- vCenter 6.5
- vCenter 6.5 U1
- vCenter 6.5 U1b
- vCenter 6.5 U1d
- vCenter 6.5 U1g
- vCenter 6.7
- vCenter 6.7 U1
- vCenter 6.7 U2a
- vCenter 6.7 U3
- vCenter 6.7 U3b
- vCenter 6.7 U3g
- vCenter 6.7.0d
- vCenter 6.7b
- vCenter 7.0
- vCenter 7.0 U1
- vCenter 7.0 U1c
- vCenter 7.0 U2
- vCenter 7.0 U2a
- vCenter 7.0 U2b
- vCenter 7.0 U3a
- vCenter 7.0 U3c
- vCenter 7.0 U3d
- vCenter 7.0d
- vCenter 8.0 GA
- vCenter 8.0 U1
- vCenter 8.0 U1b
- vCenter 8.0 U1c
- vCenter 8.0 U2
- vCenter 8.0 U2a
- vCenter 8.0b
- vCenter 8.0c
- vCenter Server 8.0 U1

- VMmark Version
- 3.0
- 3.1
- 3.1.1

- Matched Pair
- Matched Pair
- Not Matched Pair

## Filters

- Submitter
- Dell Technologies
- Fujitsu

- Total Hosts
- 2
- 3
- 4

- Total Sockets
- 2
- 3
- 4
- 8

- Total Cores
- 16
- 18
- 64
- 112
- 128
- 160
- 192
- 224
- 240
- 256
- 512

- Server Description
- Dell PowerEdge C6615
- Dell PowerEdge R7515
- Dell PowerEdge R7525
- Dell PowerEdge R7615
- Dell PowerEdge R7625
- Dell PowerEdge XR4510c
- Dell PowerEdge XR7620
- Fujitsu Server PRIMERGY RX1330 M4
- Fujitsu Server PRIMERGY RX1330 M5
- Fujitsu Server PRIMERGY RX2450 M2
- Fujitsu Server PRIMERGY RX2540 M4
- Fujitsu Server PRIMERGY RX2540 M5
- Fujitsu Server PRIMERGY RX2540 M6
- Fujitsu Server PRIMERGY RX2540 M7
- Fujitsu Server PRIMERGY RX4770 M4
- Fujitsu Server PRIMERGY RX4770 M6

- Processor Model
- AMD EPYC 7763
- AMD EPYC 7773X
- AMD EPYC 8534P
- AMD EPYC 9554
- AMD EPYC 9654P
- AMD EPYC 9754
- Intel Xeon D-2776NT
- Intel Xeon E-2186G
- Intel Xeon E-2288G
- Intel Xeon E-2388G
- Intel Xeon Gold 6448Y
- Intel Xeon Platinum 8180
- Intel Xeon Platinum 8280
- Intel Xeon Platinum 8380
- Intel Xeon Platinum 8380HL
- Intel Xeon Platinum 8490H
- Intel Xeon Platinum 8592+

- Type of Storage
- Traditional Storage
- vSAN Storage

- Hypervisor
- VMware ESXi 6.5
- VMware ESXi 6.5 U1g
- VMware ESXi 6.5 U2
- VMware ESXi 6.7 EP 06
- VMware ESXi 6.7 EP 08
- VMware ESXi 7.0 U1
- VMware ESXi 7.0 U2
- VMware ESXi 7.0 U2a
- VMware ESXi 7.0 U3
- VMware ESXi 8.0 GA
- VMware ESXi 8.0 U1
- VMware ESXi 8.0 U1a
- VMware ESXi 8.0 U2
- VMware ESXi 8.0b

- vCenter Server
- vCenter 6.5
- vCenter 6.5 U1g
- vCenter 6.7.0d
- vCenter 7.0 U1
- vCenter 7.0 U1c
- vCenter 7.0 U2
- vCenter 8.0 GA
- vCenter 8.0 U1
- vCenter 8.0 U2a
- vCenter 8.0c

- VMmark Version
- 3.0
- 3.1
- 3.1.1

- Matched Pair
- Matched Pair
- Not Matched Pair

### Filters

**Submitter**
- Dell Technologies
- Fujitsu

**Total Hosts**
- 2
- 3
- 4

**Total Sockets**
- 2
- 3
- 4
- 8

**Total Cores**
- 16
- 18
- 112
- 160
- 192
- 224
- 240
- 256
- 448

**Server Description**
- Dell PowerEdge C6615
- Dell PowerEdge R760
- Dell PowerEdge R7615
- Fujitsu Server PRIMERGY RX1330 M4
- Fujitsu Server PRIMERGY RX1330 M5
- Fujitsu Server PRIMERGY RX2540 M4
- Fujitsu Server PRIMERGY RX2540 M5
- Fujitsu Server PRIMERGY RX2540 M6
- Fujitsu Server PRIMERGY RX2540 M7
- Fujitsu Server PRIMERGY RX4770 M6

**Processor Model**
- AMD EPYC 8534P
- AMD EPYC 9654P
- Intel Xeon E-2186G
- Intel Xeon E-2288G
- Intel Xeon E-2388G
- Intel Xeon Platinum 8180
- Intel Xeon Platinum 8280
- Intel Xeon Platinum 8380
- Intel Xeon Platinum 8380HL
- Intel Xeon Platinum 8480+
- Intel Xeon Platinum 8490H

**Type of Storage**
- Traditional Storage
- vSAN Storage

**Hypervisor**
- VMware ESXi 6.5
- VMware ESXi 6.5 U2
- VMware ESXi 6.7 EP 06
- VMware ESXi 6.7 EP 08
- VMware ESXi 7.0 U1
- VMware ESXi 7.0 U2
- VMware ESXi 7.0 U3
- VMware ESXi 8.0 GA
- VMware ESXi 8.0 U2

**vCenter Server**
- vCenter 6.5
- vCenter 6.7.0d
- vCenter 7.0 U1
- vCenter 7.0 U2
- vCenter 8.0 GA
- vCenter 8.0 U2
- vCenter 8.0 U2a

**VMmark Version**
- 3.0
- 3.1
- 3.1.1

**Matched Pair**
- Matched Pair
- Not Matched Pair

### Other Related VMmark Results

**[Withdrawn VMmark 3.x Results](https://www.vmware.com/resources/vmmark/v3x-withdrawn)**

**[Previous Version (VMmark 2.x) Results](https://www.vmware.com/resources/vmmark/results2x)**

### Fair Use Guidelines

- Only official [VMmark](https://www.vmware.com/resources/vmmark) metrics and submetrics may be used in comparisons.
- Any competitive comparison of VMmark metrics must also include a statement providing the basis for making the comparison and the date when the claim is first made. A published comparison could, for example, state the claim is based on having the best VMmark result out of all results using 64 core systems, published as of the original publication date.
- Comparisons of VMmark metrics and submetrics to any other benchmark metrics are not allowed. VMmark utilizes other benchmarking software as load generators and produces results which are not comparable to the original benchmark metrics.

## All results (164)

### Performance Only (134)

| Submitter | Score | Date | Total Hosts | Total Sockets | Total Cores | Server Description | Processor Model | Type of Storage | vCenter Server | Hypervisor | VMmark Version | Primary Storage | Matched Pair | Disclosure |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| [Hewlett Packard Enterprise](https://www.hpe.com) | 40.83 @ 42 tiles | 2023-01-10 | 4 | 8 | 448 | HPE ProLiant DL380 Gen11 | Intel Xeon Platinum 8480+ | vSAN Storage | vCenter 8.0 GA | VMware ESXi 8.0a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2023-01-10-hpe-proliant-dl380gen11) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 44.51 @ 43 tiles | 2023-06-27 | 2 | 8 | 480 | HPE ProLiant DL560 Gen11 | Intel Xeon Platinum 8490H | Traditional Storage | vCenter 8.0b | VMware ESXi 8.0 U1 | 3.1.1 | SCSI Target Server - 2 x HPE ProLiant DL385 Gen11 | Yes | [PDF](https://www.vmware.com/docs/2023-06-27-hpe-proliant-dl560gen11) |
| [Dell Technologies](https://www.dell.com/) | 51.23 @ 55 tiles | 2024-02-20 | 4 | 8 | 512 | Dell PowerEdge R760 | Intel Xeon Platinum 8592+ | Traditional Storage | vCenter 8.0 U2a | VMware ESXi 8.0 U2 | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 |  | [PDF](https://www.vmware.com/docs/2024-02-20-dell-poweredge-r760-4host) |
| [Huawei](https://www.huawei.com/) | 15.83 @ 16 tiles | 2021-04-20 | 8 | 16 | 256 | Huawei FusionServer 2288H V5 | Intel Xeon Gold 6226R | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-04-20-huawei-fusionserver-2288h-v5) |
| [Supermicro](https://www.supermicro.com) | 35.20 @ 36 tiles | 2023-10-31 | 4 | 4 | 384 | Supermicro AS-1115CS-TNR | AMD EPYC 9654P | vSAN Storage | vCenter 8.0 U1c | VMware ESXi 8.0 U1a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2023-10-31-supermicro-as-1115cs-tnr) |
| [Dell EMC](https://www.dell.com/) | 29.73 @ 32 tiles | 2021-03-24 | 4 | 8 | 512 | Dell EMC PowerEdge R6525 | AMD EPYC 7713 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-03-24-dellemc-poweredge-r6525) |
| [Dell Technologies](https://www.dell.com/) | 23.64 @ 24 tiles | 2022-08-09 | 2 | 4 | 256 | Dell PowerEdge R7525 | AMD EPYC 7773X | Traditional Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U2a | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2022-08-09-dell-poweredge-r7525) |
| [Dell Technologies](https://www.dell.com/) | 40.51 @ 43 tiles | 2023-05-16 | 2 | 4 | 384 | Dell PowerEdge R7625 | AMD EPYC 9654 | Traditional Storage | vCenter 8.0c | VMware ESXi 8.0b | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2023-05-16-dell-poweredge-r7625) |
| [Dell Technologies](https://www.dell.com/) | 23.14 @ 24 tiles | 2022-04-19 | 2 | 4 | 256 | Dell PowerEdge R7525 | AMD EPYC 7773X | Traditional Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U2a | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2022-04-19-dell-poweredge-r7525) |
| [Lenovo](https://www.lenovo.com/data-center) | 40.66 @ 42 tiles | 2023-06-13 | 2 | 4 | 384 | Lenovo ThinkSystem SR665 V3 | AMD EPYC 9654 | Traditional Storage | vCenter 8.0 U1 | VMware ESXi 8.0 GA | 3.1.1 | FC SAN Storage - Lenovo Think System DM7100F Storage | Yes | [PDF](https://www.vmware.com/docs/2023-06-13-lenovo-thinksystem-sr665v3) |
| [Dell EMC](https://www.dell.com/) | 24.48 @ 26 tiles | 2022-01-07 | 4 | 8 | 320 | Dell EMC PowerEdge R750 | Intel Xeon Platinum 8380 | vSAN Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-01-07-dellemc-poweredge-r750) |
| [Supermicro](https://www.supermicro.com) | 21.01 @ 19 tiles | 2024-04-02 | 4 | 8 | 256 | Supermicro SYS-221H-TNR | Intel Xeon Gold 6548Y+ | vSAN Storage | vCenter 8.0 U2 | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-04-02-supermicro-sys-221h-tnr) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 12.23 @ 13 tiles | 2019-08-07 | 4 | 4 | 256 | HPE ProLiant DL325 Gen10 | AMD EPYC 7702 | vSAN Storage | vCenter 6.7 U3 | VMware ESXi 6.7 + AMD EPYC™ 7002 Series support | 3.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2019-08-07-hpe-proliant-dl325gen10) |
| [Dell EMC](https://www.dell.com/) | 12.42 @ 13 tiles | 2021-07-13 | 4 | 8 | 128 | Dell EMC PowerEdge R6525 | AMD EPYC 73F3 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-07-13-dellemc-poweredge-r6525) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 45.06 @ 43 tiles | 2023-10-17 | 2 | 8 | 480 | HPE ProLiant DL560 Gen11 | Intel Xeon Platinum 8490H | Traditional Storage | vCenter 8.0 U1b | VMware ESXi 8.0 U2 | 3.1.1 | SCSI Target Server - 4 x HPE ProLiant DL385 Gen11 | Yes | [PDF](https://www.vmware.com/docs/2023-10-17-hpe-proliant-dl560gen11) |
| [Supermicro](https://www.supermicro.com) | 12.18 @ 12 tiles | 2024-05-14 | 4 | 4 | 128 | Supermicro SYS-111C-NR | Intel Xeon Gold 6548Y+ | vSAN Storage | vCenter 8.0 U2 | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-05-14-supermicro-sys-111c-nr) |
| [Fujitsu](https://www.fujitsu.com) | 1.46 @ 1 tile | 2022-05-03 | 2 | 2 | 16 | Fujitsu Server PRIMERGY RX1330 M5 | Intel Xeon E-2388G | Traditional Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U3 | 3.1.1 | SCSI Target Server - Fujitsu Server PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2022-05-03-fujitsu-primergy-rx1330m5) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 15.25 @ 16 tiles | 2018-12-04 | 8 | 16 | 288 | HPE Synergy 480 Gen10 | Intel Xeon Gold 6140 | vSAN Storage | vCenter 6.7b | VMware ESXi 6.7 EP 03 | 3.0 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2018-12-04-hpe-synergy-480gen10) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 20.03 @ 20 tiles | 2021-11-30 | 2 | 8 | 224 | HPE Superdome Flex 280 | Intel Xeon Platinum 8380H | Traditional Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | SCSI Target Server - 5 x HPE ProLiant DL380 Gen9 | Yes | [PDF](https://www.vmware.com/docs/2021-11-30-hpe-superdome-flex280) |
| [World Wide Technology](https://www.wwt.com/) | 8.36 @ 9 tiles | 2019-04-22 | 4 | 8 | 176 | HPE ProLiant DL380 Gen10 (Submitted by World Wide Technology) | Intel Xeon Gold 6152 | vSAN Storage | vCenter 6.7 U1 | VMware ESXi 6.7 EP 03 | 3.0 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2019-04-22-worldwidetechnology-hpe-dl380gen10) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 50.64 @ 55 tiles | 2024-01-23 | 4 | 8 | 512 | HPE ProLiant DL380 Gen11 | Intel Xeon Platinum 8592+ | vSAN Storage | vCenter 8.0 U2a | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-01-23-hpe-proliant-dl380gen11) |
| [Fujitsu](https://www.fujitsu.com) | 45.59 @ 44 tiles | 2024-02-06 | 2 | 4 | 512 | Fujitsu Server PRIMERGY RX2450 M2 | AMD EPYC 9754 | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 U1a | 3.1.1 | SCSI Target Server - 5 x RX2540 M4; 4 x RX2540 M5; 5 x RX2540 M6 | Yes | [PDF](https://www.vmware.com/docs/2024-02-06-fujitsu-primergy-rx2450m2) |
| [Fujitsu](https://www.fujitsu.com) | 23.33 @ 24 tiles | 2022-02-08 | 2 | 4 | 256 | Fujitsu Server PRIMERGY RX2450 M1 | AMD EPYC 7763 | Traditional Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | SCSI Target Server - 5 x RX2540 M4; 3 x RX2540 M5 | Yes | [PDF](https://www.vmware.com/docs/2022-02-08-fujitsu-rx2450m1) |
| [Dell Technologies](https://www.dell.com/) | 25.34 @ 28 tiles | 2024-02-20 | 2 | 4 | 256 | Dell PowerEdge R760 | Intel Xeon Platinum 8592+ | Traditional Storage | vCenter 8.0 U2a | VMware ESXi 8.0 U2 | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2024-02-20-dell-poweredge-r760) |
| [xFusion Digital Technologies Co. Ltd](https://www.xfusion.com/en/) | 35.79 @ 36 tiles | 2024-02-06 | 4 | 8 | 480 | xFusion Digital Technologies Co. Ltd 2288H V7 | Intel Xeon Platinum 8490H | vSAN Storage | vCenter 8.0 U2 | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-02-06-xfusion-2288h-v7) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 34.22 @ 36 tiles | 2022-11-10 | 4 | 8 | 256 | HPE ProLiant DL385 Gen11 | AMD EPYC 9374F | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | SCSI Target Server - 3 x HPE ProLiant DL385 Gen10 Plus V2 |  | [PDF](https://www.vmware.com/docs/2022-11-10-hpe-proliant-dl385-gen11_4-hosts) |
| [Dell Technologies](https://www.dell.com/) | 23.85 @ 25 tiles | 2024-01-09 | 2 | 8 | 256 | Dell PowerEdge R860 | Intel Xeon Platinum 8454H | Traditional Storage | vCenter 8.0 U2 | VMware ESXi 8.0 U2 | 3.1.1 | FC SAN Storage - Dell EMC Powerstore 5000T | Yes | [PDF](https://www.vmware.com/docs/2024-01-09-dell-poweredger860) |
| [StorageReview.com](https://www.storagereview.com/) | 11.00 @ 12 tiles | 2018-01-30 | 8 | 16 | 256 | Dell EMC PowerEdge R740xd | Intel Xeon Gold 6130 | Traditional Storage | vCenter 6.5 U1b | VMware ESXi 6.5 U1 | 3.0 | FC SAN Storage - NetApp AFF A200 RAID-DP DR |  | [PDF](https://www.vmware.com/docs/2018-01-30-storagereview-com-poweredge-r740xd-datareduction) |
| [xFusion Digital Technologies Co. Ltd](https://www.xfusion.com/en/) | 31.58 @ 32 tiles | 2023-08-22 | 4 | 8 | 480 | xFusion Digital Technologies Co. Ltd 2288H V7 | Intel Xeon Platinum 8490H | vSAN Storage | vCenter 8.0 U1 | VMware ESXi 8.0 U1 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2023-08-22-xfusion-2288h-v7) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 12.78 @ 14 tiles | 2019-08-07 | 2 | 4 | 256 | HPE ProLiant DL385 Gen10 | AMD EPYC 7702 | Traditional Storage | vCenter 6.7 U3 | VMware ESXi 6.7 + AMD EPYC™ 7002 Series support | 3.1 | FC SAN Storage - HPE Nimble Storage AF80 | Yes | [PDF](https://www.vmware.com/docs/2019-08-07-hpe-proliant-dl385gen10) |
| [Dell Technologies](https://www.dell.com/) | 17.42 @ 16 tiles | 2024-01-23 | 4 | 4 | 256 | Dell PowerEdge C6615 | AMD EPYC 8534P | vSAN Storage | vCenter 8.0 U2a | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-01-23-dell-poweredge-c6615) |
| [Fujitsu](https://www.fujitsu.com) | 15.48 @ 15 tiles | 2021-11-16 | 4 | 8 | 192 | Fujitsu Server PRIMERGY CX2560 M6 | Intel Xeon Gold 5318Y | Traditional Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | SCSI Target Server - 5 x RX2540 M4; 1 x RX2540 M5 |  | [PDF](https://www.vmware.com/docs/2021-11-16-fujitsu-primergy-cx2560m6) |
| [Supermicro](https://www.supermicro.com) | 14.33 @ 16 tiles | 2024-04-02 | 4 | 4 | 128 | Supermicro AS-1115CS-TNR | AMD EPYC 9374F | vSAN Storage | vCenter 8.0 U2a | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-04-02-supermicro-as-1115cs-tnr) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 28.90 @ 31 tiles | 2023-04-04 | 4 | 4 | 256 | HPE ProLiant DL345 Gen11 | AMD EPYC 9554P | vSAN Storage | vCenter 8.0 GA | VMware ESXi 8.0b | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2023-04-04-hpe-proliant-dl345gen11) |
| [Fujitsu](https://www.fujitsu.com) | 29.84 @ 30 tiles | 2019-01-02 | 4 | 16 | 448 | Fujitsu Server PRIMEQUEST 3800E | Intel Xeon Platinum 8180M | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 02a | 3.0 | SCSI Target Server - 3x RX2540 M2; 2x RX2530 M2; 5x RX2540 M4 |  | [PDF](https://www.vmware.com/docs/2019-01-02-fujitsu-primequest3800e) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 21.53 @ 22 tiles | 2022-05-17 | 4 | 4 | 256 | HPE ProLiant DL345 Gen10 Plus | AMD EPYC 7763 | vSAN Storage | vCenter 7.0 U2b | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-05-17-hpe-proliant-dl345gen10plus) |
| [Dell Technologies](https://www.dell.com/) | 20.65 @ 21 tiles | 2023-03-21 | 2 | 2 | 192 | Dell PowerEdge R7615 | AMD EPYC 9654P | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2023-03-21-dell-poweredge-r7615) |
| [Dell EMC](https://www.dell.com/) | 18.39 @ 20 tiles | 2021-06-29 | 4 | 8 | 192 | Dell EMC PowerEdge R6525 | AMD EPYC 74F3 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-06-29-dellemc-poweredge-r6525) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 46.10 @ 48 tiles | 2019-01-29 | 24 | 48 | 864 | HPE Synergy 480 Gen10 | Intel Xeon Gold 6140 | vSAN Storage | vCenter 6.7b | VMware ESXi 6.7 EP 03 | 3.0 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2019-01-29-hpe-synergy-480gen10) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 18.31 @ 20 tiles | 2021-06-15 | 3 | 6 | 240 | HPE ProLiant DL380 Gen10 Plus | Intel Xeon Platinum 8380 | vSAN Storage | vCenter 7.0 U2a | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-06-15-hpe-proliant-dl380gen10plus) |
| [Fujitsu](https://www.fujitsu.com) | 44.69 @ 44 tiles | 2023-08-22 | 2 | 8 | 480 | Fujitsu Server PRIMERGY RX4770 M7 | Intel Xeon Platinum 8490H | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | SCSI Target Server - 2 x RX2540 M4; 4 x RX2540 M5; 5 x RX2540 M6 | Yes | [PDF](https://www.vmware.com/docs/2023-08-22-fujitsu-primergy-rx4770m7) |
| [Fujitsu](https://www.fujitsu.com) | 20.17 @ 21 tiles | 2022-03-08 | 2 | 4 | 256 | Fujitsu Server PRIMERGY RX2450 M1 | AMD EPYC 7H12 | Traditional Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | SCSI Target Server - 5 x PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2022-03-08-fujitsu-primergy-rx2450m1) |
| [Supermicro](https://www.supermicro.com) | 17.66 @ 17 tiles | 2024-04-02 | 4 | 8 | 256 | Supermicro SYS-221BT-DNTR | Intel Xeon Gold 6448Y | vSAN Storage | vCenter 8.0 U2 | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-04-02-supermicro-sys-221bt-dntr-spr) |
| [Dell EMC](https://www.dell.com/) | 24.44 @ 26 tiles | 2021-06-15 | 4 | 8 | 256 | Dell EMC PowerEdge R6525 | AMD EPYC 75F3 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-06-15-dellemc-poweredge-r6525) |
| [Fujitsu](https://www.fujitsu.com) | 12.09 @ 12 tiles | 2019-11-19 | 4 | 8 | 192 | Fujitsu Server PRIMERGY CX2560 M5 | Intel Xeon Gold 6252 | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 08 | 3.1 | SCSI Target Server - 4 x Fujitsu Server PRIMERGY RX2540 M4 |  | [PDF](https://www.vmware.com/docs/2019-11-19-fujitsu-primergy-cx2560m5) |
| [Fujitsu](https://www.fujitsu.com) | 27.52 @ 28 tiles | 2024-04-16 | 2 | 4 | 256 | Fujitsu Server PRIMERGY RX2540 M7 | Intel Xeon Platinum 8592+ | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 U2 | 3.1.1 | SCSI Target Server - 5 x RX2540 M4; 3 x RX2540 M5; 3 x RX2540 M6 | Yes | [PDF](https://www.vmware.com/docs/2024-04-16-fujitsu-primergy-rx2540m7) |
| [Fujitsu](https://www.fujitsu.com) | 14.19 @ 14 tiles | 2021-04-20 | 2 | 4 | 160 | Fujitsu Server PRIMERGY RX2540 M6 | Intel Xeon Platinum 8380 | Traditional Storage | vCenter 7.0 U1 | VMware ESXi 7.0 U2 | 3.1.1 | SCSI Target Server - 5 x RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2021-04-20-fujitsu-primergy-rx2540m6) |
| [Supermicro](https://www.supermicro.com) | 27.01 @ 27 tiles | 2023-05-02 | 4 | 8 | 416 | Supermicro SYS-221BT-DNTR | Intel Xeon Platinum 8470 | vSAN Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2023-05-02-supermicro-sys-221bt-dntr) |
| [Dell EMC](https://www.dell.com/) | 12.06 @ 13 tiles | 2022-03-21 | 2 | 2 | 128 | Dell EMC PowerEdge R7515 | AMD EPYC 7773X | Traditional Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U2a | 3.1.1 | FC SAN Storage - Dell EMC PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2022-03-21-dellemc-poweredge-r7515) |
| [Dell EMC](https://www.dell.com/) | 9.16 @ 10 tiles | 2022-02-08 | 2 | 2 | 128 | Dell EMC PowerEdge R7515 | AMD EPYC 7742 | Traditional Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U2a | 3.1.1 | FC SAN Storage - Dell EMC PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2022-02-08-dellemc-poweredge-r7515) |
| [xFusion Digital Technologies Co. Ltd](https://www.xfusion.com/en/) | 27.79 @ 28 tiles | 2022-06-28 | 4 | 16 | 448 | xFusion Digital Technologies Co. Ltd 2488H V6 | Intel Xeon Platinum 8380H | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-06-28-xfusion-2488h-v6) |
| [Supermicro](https://www.supermicro.com) | 24.26 @ 26 tiles | 2024-04-30 | 4 | 4 | 256 | Supermicro AS-1115CS-TNR | AMD EPYC 9554P | vSAN Storage | vCenter 8.0 U2a | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-04-30-supermicro-as-1115cs-tnr) |
| [Inspur](https://en.inspur.com/) | 25.25 @ 26 tiles | 2022-09-13 | 4 | 8 | 320 | Inspur InMerge1100 (Inspur NF5280M6) | Intel Xeon Platinum 8380 | vSAN Storage | vCenter 7.0 U3d | VMware ESXi 7.0 U3d | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-09-13-inspur-inmerge1100-nf5280m6) |
| [Supermicro](https://www.supermicro.com) | 18.12 @ 17 tiles | 2024-04-02 | 4 | 8 | 256 | Supermicro SYS-221BT-DNTR | Intel Xeon Gold 6548Y+ | vSAN Storage | vCenter 8.0 U2 | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-04-02-supermicro-sys-221bt-dntr-emr) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 24.26 @ 26 tiles | 2021-06-08 | 4 | 8 | 320 | HPE ProLiant DL380 Gen10 Plus | Intel Xeon Platinum 8380 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-06-08-hpe-proliant-dl380gen10plus) |
| [Dell EMC](https://www.dell.com/) | 20.04 @ 22 tiles | 2021-04-06 | 2 | 4 | 256 | Dell EMC PowerEdge R7525 | AMD EPYC 7763 | Traditional Storage | vCenter 7.0d | VMware ESXi 7.0 U2 | 3.1.1 | FC SAN Storage - Dell EMC PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2021-04-06-dellemc-poweredge-r7525) |
| [Huawei](https://www.huawei.com/) | 7.91 @ 8 tiles | 2020-12-22 | 4 | 8 | 160 | Huawei FusionServer 2288H V5 | Intel Xeon Gold 6230 | vSAN Storage | vCenter 7.0 | VMware ESXi 7.0 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2020-12-22-huawei-fusionserver-2288h-v5) |
| [Supermicro](https://www.supermicro.com) | 15.86 @ 16 tiles | 2022-02-22 | 4 | 8 | 256 | Supermicro SuperServer SYS-220BT-HNTR | Intel Xeon Platinum 8352Y | vSAN Storage | vCenter 7.0 U3a | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-02-22-supermicro-sys-220bt-hntr) |
| [xFusion Digital Technologies Co. Ltd](https://www.xfusion.com/en/) | 10.27 @ 9 tiles | 2022-08-23 | 4 | 8 | 144 | xFusion Digital Technologies Co. Ltd 2288H V6 | Intel Xeon Gold 6354 | vSAN Storage | vCenter 7.0 U3c | VMware ESXi 7.0 U3c | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-08-23-xfusion-2288h-v6) |
| [Dell EMC](https://www.dell.com/) | 13.27 @ 14 tiles | 2020-04-14 | 4 | 8 | 192 | Dell EMC PowerEdge R6525 | AMD EPYC 7F72 | vSAN Storage | vCenter 6.7 U3b | VMware ESXi 6.7 P01 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2020-04-14-dellemc-poweredge-r6525) |
| [Huawei](https://www.huawei.com/) | 10.25 @ 9 tiles | 2021-06-30 | 4 | 8 | 144 | Huawei FusionServer 2288H V6 | Intel Xeon Gold 6354 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-06-30-huawei-fusionserver-2288hv6) |
| [Dell Technologies](https://www.dell.com/) | 13.51 @ 12 tiles | 2023-01-10 | 2 | 2 | 128 | Dell PowerEdge R7615 | AMD EPYC 9554 | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2023-01-10-dell-poweredge-r7615) |
| [Hitachi Vantara](https://www.hitachivantara.com/) | 9.00 @ 9 tiles | 2019-08-12 | 4 | 8 | 224 | Hitachi Unified Compute Platform HC V124N | Intel Xeon Platinum 8276L | vSAN Storage | vCenter 6.7 U1 | VMware ESXi 6.7 EP 05 | 3.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2019-08-12-hitachi-ucphc-v124n) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 12.63 @ 12 tiles | 2023-01-10 | 4 | 4 | 128 | HPE ProLiant DL320 Gen11 | Intel Xeon Gold 6454S | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0a | 3.1.1 | SCSI Target Server - 3 x HPE ProLiant DL385 Gen10 Plus v2 |  | [PDF](https://www.vmware.com/docs/2023-01-10-hpe-proliant-dl320gen11) |
| [Dell EMC](https://www.dell.com/) | 19.40 @ 22 tiles | 2021-03-15 | 2 | 4 | 256 | Dell EMC PowerEdge R7525 | AMD EPYC 7763 | Traditional Storage | vCenter 7.0d | VMware ESXi 7.0 U2 | 3.1.1 | FC SAN Storage - Dell EMC PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2021-03-15-dellemc-poweredge-r7525) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 14.82 @ 15 tiles | 2018-02-13 | 2 | 8 | 224 | HPE ProLiant DL580 Gen10 | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.5 U1 | VMware ESXi 6.5 U1 | 3.0 | SCSI Target Server - 3 x HPE ProLiant DL380p Gen8 | Yes | [PDF](https://www.vmware.com/docs/2018-02-13-hpe-proliant-dl580gen10) |
| [Lenovo](https://www.lenovo.com/data-center) | 19.53 @ 21 tiles | 2021-03-15 | 2 | 4 | 256 | Lenovo ThinkSystem SR665 | AMD EPYC 7763 | Traditional Storage | vCenter 7.0 | VMware ESXi 7.0 U2 | 3.1.1 | FC SAN Storage - Lenovo ThinkSystem DM7100F Storage | Yes | [PDF](https://www.vmware.com/docs/2021-03-15-lenovo-thinksystem-sr665) |
| [Inspur](https://en.inspur.com/) | 25.74 @ 26 tiles | 2022-10-04 | 4 | 8 | 320 | Inspur InMerge1100 (Inspur NF5280M6) | Intel Xeon Platinum 8380 | vSAN Storage | vCenter 7.0 U3d | VMware ESXi 7.0 U3d | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-10-04-inspur-inmerge1100-nf5280m6) |
| [xFusion Digital Technologies Co. Ltd](https://www.xfusion.com/en/) | 8.46 @ 8 tiles | 2022-05-04 | 4 | 8 | 192 | xFusion Digital Technologies Co. Ltd 2288H V5 | Intel Xeon Gold 6252 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-05-04-xfusion-2288hv5) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 16.91 @ 18 tiles | 2019-07-02 | 6 | 12 | 288 | HPE Synergy 480 Gen10 | Intel Xeon Gold 6252 | Traditional Storage | vCenter 6.7 U1 | VMware ESXi 6.7 EP 06 | 3.1 | FC SAN Storage - HPE 3PAR StoreServ 9450 |  | [PDF](https://www.vmware.com/docs/2019-07-02-hpe-synergy-480gen10) |
| [xFusion Digital Technologies Co. Ltd](https://www.xfusion.com/en/) | 34.07 @ 32 tiles | 2023-09-05 | 4 | 8 | 480 | xFusion Digital Technologies Co. Ltd 2288H V7 | Intel Xeon Platinum 8490H | vSAN Storage | vCenter 8.0 U1 | VMware ESXi 8.0 U1 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2023-09-05-xfusion-2288h-v7) |
| [Quanta Cloud Technology](https://www.qct.io/) | 8.24 @ 9 tiles | 2019-11-04 | 4 | 8 | 192 | QuantaGrid D52B-1U | Intel Xeon Gold 6252 | vSAN Storage | vCenter 6.7 U3 | VMware ESXi 6.7 U3 | 3.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2019-11-04-quantacloudtechnology-quantagrid-d52b-1u) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 7.93 @ 8 tiles | 2018-08-16 | 2 | 4 | 112 | HPE Synergy 480 Gen10 | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.7 | VMware ESXi 6.5 U2 | 3.0 | SCSI Target Server - 2 x HPE ProLiant DL380 Gen9 | Yes | [PDF](https://www.vmware.com/docs/2018-08-16-hpe-synergy-480gen10) |
| [Fujitsu](https://www.fujitsu.com) | 23.38 @ 23 tiles | 2023-03-21 | 2 | 4 | 240 | Fujitsu Server PRIMERGY RX2540 M7 | Intel Xeon Platinum 8490H | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | SCSI Target Server - 5 x PRIMERGY RX2540 M4; 3 x RX2540 M5 | Yes | [PDF](https://www.vmware.com/docs/2023-03-21-fujitsu-primergy-rx2540m7) |
| [Dell Technologies](https://www.dell.com/) | 44.15 @ 49 tiles | 2023-06-13 | 2 | 4 | 512 | Dell PowerEdge R7625 | AMD EPYC 9754 | Traditional Storage | vCenter 8.0 U1 | VMware ESXi 8.0 U1 | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2023-06-13-dell-poweredge-r7625) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 6.99 @ 8 tiles | 2017-07-11 | 2 | 4 | 112 | HPE ProLiant DL380 Gen10 | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.5 | VMware ESXi 6.5.0d | 3.0 | SCSI Target Server - 5 x HPE ProLiant DL380p Gen9 | Yes | [PDF](https://www.vmware.com/docs/2017-07-11-hpe-proliant-dl380gen10) |
| [Dell EMC](https://www.dell.com/) | 6.07 @ 6 tiles | 2021-08-24 | 4 | 8 | 64 | Dell EMC PowerEdge R6525 | AMD EPYC 72F3 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-08-24-dellemc-poweredge-r6525) |
| [Fujitsu](https://www.fujitsu.com) | 1.38 @ 1 tile | 2019-11-01 | 2 | 2 | 16 | Fujitsu Server PRIMERGY RX1330 M4 | Intel Xeon E-2288G | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 08 | 3.1 | SCSI Target Server - 1 x Fujitsu Server PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2019-11-01-fujitsu-rx1330m4) |
| [StorageReview.com](https://www.storagereview.com/) | 12.43 @ 12 tiles | 2018-01-02 | 8 | 16 | 256 | Dell EMC PowerEdge R740xd | Intel Xeon Gold 6130 | Traditional Storage | vCenter 6.5 U1b | VMware ESXi 6.5 U1 | 3.0 | FC SAN Storage - Dell EMC Unity 450F RAID5 |  | [PDF](https://www.vmware.com/docs/2018-01-02-storagereview-com-poweredge-r740xd-raid5) |
| [Fujitsu](https://www.fujitsu.com) | 8.11 @ 8 tiles | 2018-01-02 | 2 | 4 | 112 | Fujitsu Server PRIMERGY RX2540 M4 | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.5 | VMware ESXi 6.5 | 3.0 | SCSI Target Server - 3 x Fujitsu Server PRIMERGY RX2540 M2 | Yes | [PDF](https://www.vmware.com/docs/2018-01-02-fujitsu-rx2540m4) |
| [Dell Technologies](https://www.dell.com/) | 18.78 @ 20 tiles | 2023-01-17 | 2 | 4 | 224 | Dell PowerEdge R760 | Intel Xeon Platinum 8480+ | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | FC SAN Storage - Dell EMC PowerVault ME4024 | Yes | [PDF](https://www.vmware.com/docs/2023-01-17-dell-poweredge-r760) |
| [Fujitsu](https://www.fujitsu.com) | 14.86 @ 15 tiles | 2018-07-18 | 2 | 8 | 224 | Fujitsu Server PRIMERGY RX4770 M4 | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.5 U1g | VMware ESXi 6.5 U1g | 3.0 | SCSI Target Server - 3 x PRIMERGY RX2540 M2; 1 x TX2560 M2 | Yes | [PDF](https://www.vmware.com/docs/2018-07-18-fujitsu-rx4770m4) |
| [Dell Technologies](https://www.dell.com/) | 16.39 @ 16 tiles | 2022-06-28 | 4 | 8 | 256 | Dell PowerEdge T550 | Intel Xeon Gold 6338 | vSAN Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U3c | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-06-28-dell-poweredge-t550) |
| [Supermicro](https://www.supermicro.com) | 24.34 @ 24 tiles | 2022-07-12 | 4 | 8 | 320 | Supermicro SuperServer SYS-220BT-DNTR | Intel Xeon Platinum 8380 | vSAN Storage | vCenter 7.0 U3a | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-07-12-supermicro-superserver-sys-220bt-dntr) |
| [Dell EMC](https://www.dell.com/) | 39.01 @ 40 tiles | 2021-08-10 | 4 | 8 | 512 | Dell EMC PowerEdge R6525 | AMD EPYC 7763 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-08-10-dellemc-poweredge-r6525) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 40.19 @ 44 tiles | 2022-11-10 | 2 | 4 | 384 | HPE ProLiant DL385 Gen11 | AMD EPYC 9654 | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | FC SAN Storage - HPE Alletra 9060 | Yes | [PDF](https://www.vmware.com/docs/2022-11-10-hpe-proliant-dl385-gen11_2-hosts) |
| [Dell EMC](https://www.dell.com/) | 11.34 @ 12 tiles | 2022-02-23 | 2 | 2 | 128 | Dell EMC PowerEdge R7515 | AMD EPYC 7763 | Traditional Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U2a | 3.1.1 | FC SAN Storage - Dell EMC PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2022-02-23-dellemc-poweredge-r7515) |
| [Dell EMC](https://www.dell.com/) | 24.08 @ 28 tiles | 2020-04-28 | 4 | 8 | 512 | Dell EMC PowerEdge R6525 | AMD EPYC 7742 | vSAN Storage | vCenter 6.7 U3b | VMware ESXi 6.7 P01 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2020-04-28-dellemc-poweredge-r6525) |
| [Dell EMC](https://www.dell.com/) | 13.82 @ 14 tiles | 2021-08-24 | 2 | 4 | 160 | Dell EMC PowerEdge R750 | Intel Xeon Platinum 8380 | Traditional Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U2 | 3.1.1 | FC SAN Storage - Dell EMC PowerVault ME4024 | Yes | [PDF](https://www.vmware.com/docs/2021-08-24-dellemc-poweredge-r750) |
| [StorageReview.com](https://www.storagereview.com/) | 10.85 @ 10 tiles | 2018-06-26 | 8 | 16 | 256 | Dell EMC PowerEdge R740xd | Intel Xeon Gold 6130 | Traditional Storage | vCenter 6.5 U1b | VMware ESXi 6.5 U1g | 3.0 | FC SAN Storage - QSAN XS5226 |  | [PDF](https://www.vmware.com/docs/2018-06-26-storagereview-com-poweredge-r740xd-qsan-xs5226) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 30.13 @ 32 tiles | 2018-12-18 | 16 | 32 | 576 | HPE Synergy 480 Gen10 | Intel Xeon Gold 6140 | vSAN Storage | vCenter 6.7b | VMware ESXi 6.7 EP 03 | 3.0 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2018-12-18-hpe-synergy-480gen10) |
| [Dell EMC](https://www.dell.com/) | 13.95 @ 14 tiles | 2021-06-29 | 2 | 4 | 160 | Dell EMC PowerEdge R750 | Intel Xeon Platinum 8380 | Traditional Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U2 | 3.1.1 | FC SAN Storage - Dell EMC PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2021-06-29-dellemc-poweredge-r750) |
| [Fujitsu](https://www.fujitsu.com) | 19.72 @ 20 tiles | 2020-10-22 | 2 | 8 | 224 | Fujitsu Server PRIMERGY RX4770 M6 | Intel Xeon Platinum 8380HL | Traditional Storage | vCenter 7.0 U1 | VMware ESXi 7.0 U1 | 3.1.1 | SCSI Target Server - 5 x RX2540 M4; 2 x RX2540 M5 | Yes | [PDF](https://www.vmware.com/docs/2020-10-22-fujitsu-rx4770m6) |
| [Dell EMC](https://www.dell.com/) | 15.18 @ 16 tiles | 2020-10-06 | 4 | 4 | 256 | Dell EMC PowerEdge R7515 | AMD EPYC 7742 | vSAN Storage | vCenter 6.7 U3b | VMware ESXi 6.7 P01 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2020-10-06-dellemc-poweredge-r7515) |
| [Fujitsu](https://www.fujitsu.com) | 28.11 @ 29 tiles | 2018-12-04 | 4 | 16 | 448 | Fujitsu Server PRIMEQUEST 3800E | Intel Xeon Platinum 8180M | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 02a | 3.0 | SCSI Target Server - 3x RX2540 M2; 2x RX2530 M2; 5x RX2540 M4 |  | [PDF](https://www.vmware.com/docs/2018-12-04-fujitsu-primequest3800e) |
| [Sirius Computer Solutions](https://www.siriuscom.com/) | 8.70 @ 9 tiles | 2021-04-06 | 4 | 8 | 144 | Dell EMC PowerEdge R740xd | Intel Xeon Gold 6240 | vSAN Storage | vCenter 6.7 U3g | VMware ESXi 6.7 P04 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-04-06-siriuscomputersolutions-poweredge-r740xd) |
| [Quanta Cloud Technology](https://www.qct.io/) | 5.23 @ 6 tiles | 2020-01-14 | 4 | 8 | 144 | QuantaPlex T42S-2U | Intel Xeon Gold 5220 | vSAN Storage | vCenter 6.7 U3 | VMware ESXi 6.7 U3 | 3.1 | VMware vSAN - Hybrid |  | [PDF](https://www.vmware.com/docs/2020-01-14-quantacloudtechnology-quantaplex-t42s-2u) |
| [Fujitsu](https://www.fujitsu.com) | 11.45 @ 11 tiles | 2018-09-25 | 4 | 8 | 208 | Fujitsu Server PRIMERGY CX2560 M4 | Intel Xeon Platinum 8164 | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 02a | 3.0 | SCSI Target Server - 3x PRIMERGY RX2540 M2; PRIMEQUEST 2800E3 |  | [PDF](https://www.vmware.com/docs/2018-09-25-fujitsu-primergy-cx2560m4) |
| [Dell EMC](https://www.dell.com/) | 13.74 @ 16 tiles | 2021-02-09 | 4 | 4 | 256 | Dell EMC PowerEdge C6525 | AMD EPYC 7702P | vSAN Storage | vCenter 6.7 U3b | VMware ESXi 6.7 P04 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-02-09-dellemc-poweredge-c6525) |
| [Dell EMC](https://www.dell.com/) | 63.01 @ 64 tiles | 2021-05-04 | 8 | 16 | 1024 | Dell EMC PowerEdge R6525 | AMD EPYC 7713 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-05-04-dellemc-poweredge-r6525) |
| [Dell EMC](https://www.dell.com/) | 38.21 @ 39 tiles | 2021-07-27 | 4 | 8 | 512 | Dell EMC PowerEdge R6525 | AMD EPYC 7763 | vSAN Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U2a | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2021-07-27-dellemc-poweredge-r6525) |
| [StorageReview.com](https://www.storagereview.com/) | 10.56 @ 10 tiles | 2018-06-26 | 8 | 16 | 256 | Dell EMC PowerEdge R740xd | Intel Xeon Gold 6130 | Traditional Storage | vCenter 6.5 U1b | VMware ESXi 6.5 U1g | 3.0 | FC SAN Storage - Fujitsu AF250S2 |  | [PDF](https://www.vmware.com/docs/2018-06-26-storagereview-com-poweredge-r740xd-fujitsu-af250s2) |
| [Fujitsu](https://www.fujitsu.com) | 17.23 @ 18 tiles | 2019-08-27 | 2 | 8 | 224 | Fujitsu Server PRIMERGY RX4770 M5 | Intel Xeon Platinum 8280 | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 08 | 3.1 | SCSI Target Server - 6 x Fujitsu Server PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2019-08-27-fujitsu-rx4770m5) |
| [Lenovo](https://www.lenovo.com/data-center) | 9.10 @ 10 tiles | 2019-09-17 | 2 | 2 | 128 | Lenovo ThinkSystem SR655 | AMD EPYC 7742 | Traditional Storage | vCenter 6.7 U3 | VMware ESXi 6.7 U3 | 3.1 | FC SAN Storage - Lenovo ThinkSystem DM7000F Storage | Yes | [PDF](https://www.vmware.com/docs/2019-09-17-lenovo-thinksystem-sr655) |
| [Lenovo](https://www.lenovo.com/data-center) | 18.23 @ 19 tiles | 2020-11-17 | 2 | 4 | 256 | Lenovo ThinkSystem SR665 | AMD EPYC 7H12 | Traditional Storage | vCenter 7.0 | VMware ESXi 6.7 EP 15 | 3.1.1 | FC SAN Storage - Lenovo ThinkSystem DM7100F Storage | Yes | [PDF](https://www.vmware.com/docs/2020-11-17-lenovo-thinksystem-sr665) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 33.58 @ 36 tiles | 2021-03-15 | 4 | 8 | 512 | HPE ProLiant DL385 Gen10 Plus v2 | AMD EPYC 7763 | Traditional Storage | vCenter 7.0 U1 | VMware ESXi 6.7 P04 | 3.1.1 | FC SAN Storage - HPE 3PAR 9450 |  | [PDF](https://www.vmware.com/docs/2021-03-15-hpe-proliant-dl385gen10plusv2) |
| [Lenovo](https://www.lenovo.com/data-center) | 21.58 @ 24 tiles | 2021-05-04 | 2 | 4 | 256 | Lenovo ThinkSystem SR665 | AMD EPYC 7763 | Traditional Storage | vCenter 7.0 | VMware ESXi 7.0 U2 | 3.1.1 | FC SAN Storage - Lenovo ThinkSystem DM7100F Storage | Yes | [PDF](https://www.vmware.com/docs/2021-05-04-lenovo-thinksystem-sr665) |
| [Supermicro](https://www.supermicro.com) | 7.39 @ 8 tiles | 2019-10-08 | 4 | 8 | 160 | Supermicro SYS-1029U-TN10RT | Intel Xeon Gold 6230 | vSAN Storage | vCenter 6.7 U2a | VMware ESXi 6.7 U3 | 3.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2019-10-08-supermicro-sys-1029u-tn10rt) |
| [Quanta Cloud Technology](https://www.qct.io/) | 3.45 @ 4 tiles | 2018-11-01 | 4 | 8 | 112 | Quanta Cloud Technology QuantaPlex T42S-2U | Intel Xeon Gold 5120 | vSAN Storage | vCenter 6.5 U1g | VMware ESXi 6.5 U1g | 3.0 | VMware vSAN - Hybrid |  | [PDF](https://www.vmware.com/docs/2018-11-01-quantacloudtechnology-quantaplex-t42s-2u) |
| [StorageReview.com](https://www.storagereview.com/) | 12.11 @ 12 tiles | 2018-01-02 | 8 | 16 | 256 | Dell EMC PowerEdge R740xd | Intel Xeon Gold 6130 | Traditional Storage | vCenter 6.5 U1b | VMware ESXi 6.5 U1 | 3.0 | FC SAN Storage - Dell EMC Unity 450F RAID10 |  | [PDF](https://www.vmware.com/docs/2018-01-02-storagereview-com-poweredge-r740xd-raid10) |
| [Dell EMC](https://www.dell.com/) | 14.71 @ 15 Tiles | 2018-06-06 | 2 | 8 | 224 | Dell EMC PowerEdge R940 | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.7 | VMware ESXi 6.7 | 3.0 | SCSI Target Server - 5 x Dell PowerEdge R730 | Yes | [PDF](https://www.vmware.com/docs/2018-06-06-dellemc-poweredge-r940) |
| [IEIT SYSTEMS Co. Ltd](https://www.ieisystem.com/) | 51.94 @ 55 tiles | 2024-06-11 | 4 | 8 | 512 | IEIT Systems Co. Ltd inMerge1100M7S | Intel Xeon Platinum 8592+ | vSAN Storage | vCenter 8.0 U2a | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-06-11-ieit-inmerge1100m7s) |
| [Supermicro](https://www.supermicro.com) | 7.70 @ 9 tiles | 2018-02-12 | 4 | 8 | 128 | Supermicro SuperServer SYS-2029BT-HNC0R | Intel Xeon Gold 6142 | vSAN Storage | vCenter 6.5 U1d | VMware ESXi 6.5 U1 | 3.0 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2018-02-12-supermicro-superserver-sys-2029bt-hnc0r) |
| [Fujitsu](https://www.fujitsu.com) | 9.02 @ 9 tiles | 2019-04-02 | 2 | 4 | 112 | Fujitsu Server PRIMERGY RX2540 M5 | Intel Xeon Platinum 8280 | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 06 | 3.1 | SCSI Target Server - 4 x Fujitsu Server PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2019-04-02-fujitsu-rx2540m5) |
| [Fujitsu](https://www.fujitsu.com) | 33.04 @ 35 tiles | 2019-06-14 | 2 | 16 | 448 | Fujitsu Server PRIMEQUEST 3800E2 | Intel Xeon Platinum 8280 | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 06 | 3.1 | SCSI Target Server - 6x RX2540 M4; 2x RX2540 M5; 2x RX2540 M2 | Yes | [PDF](https://www.vmware.com/docs/2019-06-14-fujitsu-primequest3800e2) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 8.01 @ 8 tiles | 2018-03-13 | 2 | 4 | 112 | HPE ProLiant DL380 Gen10 | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.5 U1 | VMware ESXi 6.5 Patch 02 | 3.0 | SCSI Target Server - 2 x HPE ProLiant DL380p Gen8 | Yes | [PDF](https://www.vmware.com/docs/2018-03-13-hpe-proliant-dl380gen10) |
| [Quanta Cloud Technology](https://www.qct.io/) | 8.51 @ 9 tiles | 2017-12-20 | 4 | 8 | 176 | QuantaGrid D52B-1U | Intel Xeon Gold 6152 | vSAN Storage | vCenter 6.5 U1 | VMware ESXi 6.5 U1 | 3.0 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2017-12-20-quantacloudtechnology-quantagrid-d52b1u) |
| [Hewlett Packard Enterprise](https://www.hpe.com) | 5.88 @ 6 tiles | 2017-06-20 | 2 | 4 | 88 | HPE ProLiant DL380 Gen9 | Intel Xeon E5-2699A v4 | Traditional Storage | vCenter 6.5 | VMware ESXi 6.5 | 3.0 | SCSI Target Server - 5 x HPE ProLiant DL380p Gen9 | Yes | [PDF](https://www.vmware.com/docs/2017-06-20-hpe-proliant-dl380gen9) |
| Sugon | 6.95 @ 7 tiles | 2018-03-28 | 4 | 8 | 128 | Sugon I620-G30 | Intel Xeon Gold 6130 | vSAN Storage | vCenter 6.5 U1 | VMware ESXi 6.5 Patch 2 | 3.0 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2018-03-28-sugon-i620-g30) |
| [StorageReview.com](https://www.storagereview.com/) | 11.58 @ 12 tiles | 2018-01-30 | 8 | 16 | 256 | Dell EMC PowerEdge R740xd | Intel Xeon Gold 6130 | Traditional Storage | vCenter 6.5 U1b | VMware ESXi 6.5 U1 | 3.0 | FC SAN Storage - NetApp AFF A200 RAID-DP |  | [PDF](https://www.vmware.com/docs/2018-01-30-storagereview-com-poweredge-r740xd) |
| [StorageReview.com](https://www.storagereview.com/) | 1.22 @ 1 tile | 2018-01-16 | 2 | 4 | 64 | Dell EMC PowerEdge R740xd | Intel Xeon Gold 6130 | Traditional Storage | vCenter 6.5 U1b | VMware ESXi 6.5 U1 | 3.0 | FC SAN Storage - Seagate AssuredSAN 4824 RAID1 | Yes | [PDF](https://www.vmware.com/docs/2018-01-16-storagereview-com-poweredge-r740xd) |
| [Fujitsu](https://www.fujitsu.com) | 1.41 @ 1 tile | 2018-11-06 | 3 | 3 | 18 | Fujitsu Server PRIMERGY RX1330 M4 | Intel Xeon E-2186G | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.5 U2 | 3.0 | SCSI Target Server - 1 x Fujitsu Server PRIMERGY TX2560 M2 |  | [PDF](https://www.vmware.com/docs/2018-11-06-fujitsu-rx1330m4) |
| [Dell EMC](https://www.dell.com/) | 7.45 @ 8 tiles | 2017-11-08 | 2 | 4 | 112 | Dell EMC PowerEdge R740xd | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.5 U1 | VMware ESXi 6.5.0a | 3.0 | SCSI Target Server - 2 x Dell EMC PowerEdge R720 | Yes | [PDF](https://www.vmware.com/docs/2017-11-08-dell-poweredge-r740xd) |
| [IEIT SYSTEMS Co. Ltd](https://www.ieisystem.com/) | 52.75 @ 55 tiles | 2024-07-09 | 4 | 8 | 512 | IEIT Systems Co. Ltd inMerge1100M7S | Intel Xeon Platinum 8592+ | vSAN Storage | vCenter 8.0 U2a | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-07-09-IEIT-inMerge1100M7S) |
| [Supermicro](https://www.supermicro.com) | 26.95 @ 26 tiles | 2024-05-14 | 2 | 4 | 192 | Supermicro AS-2125HS-TNR | AMD EPYC 9474F | Traditional Storage | vCenter 8.0 U2 | VMware ESXi 8.0 U2 | 3.1.1 | FC SAN Storage - Pure Storage FlashArray FA-X90R2 | Yes | [PDF](https://www.vmware.com/docs/2024-05-14-supermicro-as-2125hs-tnr) |
| [Supermicro](https://www.supermicro.com) | 24.74 @ 24 tiles | 2024-01-09 | 2 | 4 | 192 | Supermicro AS-2125HS-TNR | AMD EPYC 9454 | Traditional Storage | vCenter 8.0 U1 | VMware ESXi 8.0b | 3.1.1 | FC SAN Storage - Pure Storage FlashArray FA-X90R2 | Yes | [PDF](https://www.vmware.com/docs/2024-01-09-supermicro-as-2125hs-tnr) |
| [Supermicro](https://www.supermicro.com) | 32.79 @ 32 tiles | 2023-11-14 | 2 | 4 | 256 | Supermicro AS-2125HS-TNR | AMD EPYC 9554 | Traditional Storage | vCenter 8.0 U1 | VMware ESXi 8.0b | 3.1.1 | FC SAN Storage - Pure Storage FlashArray FA-X90R2 | Yes | [PDF](https://www.vmware.com/docs/2023-11-14-supermicro-as-2125hs-tnr) |
| [Supermicro](https://www.supermicro.com) | 9.10 @ 9 tiles | 2023-10-03 | 2 | 4 | 64 | Supermicro AS-2125HS-TNR | AMD EPYC 9174F | Traditional Storage | vCenter Server 8.0 U1 | VMware ESXi 8.0b | 3.1.1 | FC SAN Storage - Pure Storage FlashArray FA-X90R2 | Yes | [PDF](https://www.vmware.com/docs/2023-10-03-supermicro-as-2125hs-tnr) |
| [Supermicro](https://www.supermicro.com) | 18.21 @ 18 tiles | 2023-09-19 | 2 | 4 | 128 | Supermicro AS-2125HS-TNR | AMD EPYC 9374F | Traditional Storage | vCenter 8.0 U1 | VMware ESXi 8.0b | 3.1.1 | FC SAN Storage - Pure Storage FlashArray FA-X90R2 | Yes | [PDF](https://www.vmware.com/docs/2023-09-19-supermicro-as-2125hs-tnr) |
| [Supermicro](https://www.supermicro.com) | 32.75 @ 32 tiles | 2023-08-22 | 2 | 4 | 256 | Supermicro AS-2125HS-TNR | AMD EPYC 9554 | Traditional Storage | vCenter 8.0 U1 | VMware ESXi 8.0b | 3.1.1 | FC SAN Storage - Pure Storage FlashArray FA-X90R2 | Yes | [PDF](https://www.vmware.com/docs/2023-08-22-supermicro-as-2125hs-tnr) |
| [Supermicro](https://www.supermicro.com) | 47.78 @ 46 tiles | 2023-07-11 | 2 | 4 | 384 | Supermicro AS-2125HS-TNR | AMD EPYC 9684X | Traditional Storage | vCenter 8.0 U1 | VMware ESXi 8.0b | 3.1.1 | FC SAN Storage - Pure Storage FlashArray FA-X90R2 | Yes | [PDF](https://www.vmware.com/docs/2023-07-11-supermicro-as-2125hs-tnr) |
| [Supermicro](https://www.supermicro.com) | 7.61 @ 9 tiles | 2018-02-26 | 4 | 8 | 128 | Supermicro Superserver SYS-2029BT-HNR | Intel Xeon Gold 6142 | vSAN Storage | vCenter 6.5 U1d | VMware ESXi 6.5 U1 | 3.0 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2018-02-26-supermicro-sys-2029bt-hnr) |
| [Supermicro](https://www.supermicro.com) | 9.95 @ 11 tiles | 2020-06-02 | 4 | 8 | 192 | Supermicro Superserver SYS-2029BT-HNR | Intel Xeon Gold 6252 | Traditional Storage | vCenter 6.7 U3b | VMware ESXi 6.7 P01 | 3.1.1 | Mixed - VMware vSAN All Flash; NFS - Supermicro SYS-1029P-N32R |  | [PDF](https://www.vmware.com/docs/2020-06-02-supermicro-sys-2029bt-hnr) |
| [Supermicro](https://www.supermicro.com) | 10.63 @ 12 tiles | 2020-06-30 | 4 | 8 | 192 | Supermicro Superserver SYS-2029BT-HNR | Intel Xeon Platinum 8268 | vSAN Storage | vCenter 7.0 | VMware ESXi 7.0 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2020-06-30-supermicro-sys-2029bt-hnr) |

### Server Power-Performance (19)

| Submitter | Score | Date | Total Hosts | Total Sockets | Total Cores | Server Description | Processor Model | Type of Storage | vCenter Server | Hypervisor | VMmark Version | Primary Storage | Matched Pair | Disclosure |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| [Fujitsu](https://www.fujitsu.com) | 7.1922 PPKW @ 14 tiles | 2021-04-20 | 2 | 4 | 160 | Fujitsu Server PRIMERGY RX2540 M6 | Intel Xeon Platinum 8380 | Traditional Storage | vCenter 7.0 U1 | VMware ESXi 7.0 U2 | 3.1.1 | SCSI Target Server - 5 x RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2021-04-20-fujitsu-primergy-rx2540m6-serverppkw) |
| [Dell Technologies](https://www.dell.com/) | 6.1093 PPKW @ 14 tiles | 2023-05-16 | 2 | 4 | 128 | Dell PowerEdge XR7620 | Intel Xeon Gold 6448Y | vSAN Storage | vCenter 8.0c | VMware ESXi 8.0b | 3.1.1 | VMware vSAN - All Flash | Yes | [PDF](https://www.vmware.com/docs/2023-05-16-dell-poweredge-xr7620) |
| [Dell Technologies](https://www.dell.com/) | 21.0179 PPKW @ 21 tiles | 2023-03-21 | 2 | 2 | 192 | Dell PowerEdge R7615 | AMD EPYC 9654P | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2023-03-21-dell-poweredge-r7615-serverppkw) |
| [Fujitsu](https://www.fujitsu.com) | 5.9120 PPKW @ 15 tiles | 2018-07-18 | 2 | 8 | 224 | Fujitsu Server PRIMERGY RX4770 M4 | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.5 U1g | VMware ESXi 6.5 U1g | 3.0 | SCSI Target Server - 3 x PRIMERGY RX2540 M2; 1 x TX2560 M2 | Yes | [PDF](https://www.vmware.com/docs/2018-07-18-fujitsu-rx4770m4-serverppkw) |
| [Fujitsu](https://www.fujitsu.com) | 6.3858 PPKW @ 1 tile | 2022-05-03 | 2 | 2 | 16 | Fujitsu Server PRIMERGY RX1330 M5 | Intel Xeon E-2388G | Traditional Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U3 | 3.1.1 | SCSI Target Server - Fujitsu Server PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2022-05-03-fujitsu-primergy-rx1330m5-serverppkw) |
| [Fujitsu](https://www.fujitsu.com) | 6.3290 PPKW @ 9 tiles | 2019-04-02 | 2 | 4 | 112 | Fujitsu Server PRIMERGY RX2540 M5 | Intel Xeon Platinum 8280 | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 06 | 3.1 | SCSI Target Server - 4 x Fujitsu Server PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2019-04-02-fujitsu-rx2540m5-serverppkw) |
| [Fujitsu](https://www.fujitsu.com) | 6.3410 PPKW @ 20 tiles | 2020-10-22 | 2 | 8 | 224 | Fujitsu Server PRIMERGY RX4770 M6 | Intel Xeon Platinum 8380HL | Traditional Storage | vCenter 7.0 U1 | VMware ESXi 7.0 U1 | 3.1.1 | SCSI Target Server - 5 x RX2540 M4; 2 x RX2540 M5 | Yes | [PDF](https://www.vmware.com/docs/2020-10-22-fujitsu-rx4770m6-serverppkw) |
| [Fujitsu](https://www.fujitsu.com) | 6.0863 PPKW @ 8 tiles | 2018-01-02 | 2 | 4 | 112 | Fujitsu Server PRIMERGY RX2540 M4 | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.5 | VMware ESXi 6.5 | 3.0 | SCSI Target Server - 3 x Fujitsu Server PRIMERGY RX2540 M2 | Yes | [PDF](https://www.vmware.com/docs/2018-01-02-fujitsu-rx2540m4-serverppkw) |
| [Fujitsu](https://www.fujitsu.com) | 3.4996 PPKW @ 1 tile | 2018-11-06 | 3 | 3 | 18 | Fujitsu Server PRIMERGY RX1330 M4 | Intel Xeon E-2186G | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.5 U2 | 3.0 | SCSI Target Server - 1 x Fujitsu Server PRIMERGY TX2560 M2 |  | [PDF](https://www.vmware.com/docs/2018-11-06-fujitsu-rx1330m4-serverppkw) |
| [Dell Technologies](https://www.dell.com/) | 4.0285 PPKW @ 4 tiles | 2022-11-29 | 4 | 4 | 64 | Dell PowerEdge XR4510c | Intel Xeon D-2776NT | vSAN Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2022-11-29-dell-poweredge-xr4510c-serverppkw) |
| [Dell Technologies](https://www.dell.com/) | 12.1753 PPKW @ 12 tiles | 2023-01-10 | 2 | 2 | 128 | Dell PowerEdge R7615 | AMD EPYC 9554 | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2023-01-10-dell-poweredge-r7615-serverppkw) |
| [Dell Technologies](https://www.dell.com/) | 12.8592 PPKW @ 48 tiles | 2023-06-13 | 2 | 4 | 512 | Dell PowerEdge R7625 | AMD EPYC 9754 | Traditional Storage | vCenter 8.0 U1 | VMware ESXi 8.0 U1 | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2023-06-13-dell-poweredge-r7625-serverppkw) |
| [Fujitsu](https://www.fujitsu.com) | 11.4640 PPKW @ 28 tiles | 2024-04-30 | 2 | 4 | 256 | Fujitsu Server PRIMERGY RX2540 M7 | Intel Xeon Platinum 8592+ | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 U2 | 3.1.1 | SCSI Target Server - 5 x RX2540 M4; 3 x RX2540 M5; 3 x RX2540 M6 | Yes | [PDF](https://www.vmware.com/docs/2024-04-30-fujitsu-primergy-rx2540-m7-serverppkw) |
| [Fujitsu](https://www.fujitsu.com) | 3.9262 PPKW @ 1 tile | 2019-11-01 | 2 | 2 | 16 | Fujitsu Server PRIMERGY RX1330 M4 | Intel Xeon E-2288G | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 08 | 3.1 | SCSI Target Server - 1 x Fujitsu Server PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2019-11-01-fujitsu-rx1330m4-serverppkw) |
| [Fujitsu](https://www.fujitsu.com) | 14.2452 PPKW @ 44 tiles | 2024-02-06 | 2 | 4 | 512 | Fujitsu Server PRIMERGY RX2450 M2 | AMD EPYC 9754 | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 U1a | 3.1.1 | SCSI Target Server - 5 x RX2540 M4; 4 x RX2540 M5; 5 x RX2540 M6 | Yes | [PDF](https://www.vmware.com/docs/2024-02-06-fujitsu-primergy-rx2450m2-serverppkw) |
| [Fujitsu](https://www.fujitsu.com) | 9.7059 PPKW @ 22 tiles | 2023-03-21 | 2 | 4 | 240 | Fujitsu Server PRIMERGY RX2540 M7 | Intel Xeon Platinum 8490H | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | SCSI Target Server - 5 x PRIMERGY RX2540 M4; 3 x RX2540 M5 | Yes | [PDF](https://www.vmware.com/docs/2023-03-21-fujitsu-primergy-rx2540m7-serverppkw) |
| [Dell Technologies](https://www.dell.com/) | 10.3390 PPKW @ 24 tiles | 2022-09-06 | 2 | 4 | 256 | Dell PowerEdge R7525 | AMD EPYC 7773X | Traditional Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U2a | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2022-09-06-dell-poweredge-r7525-serverppkw) |
| [Dell Technologies](https://www.dell.com/) | 8.1263 PPKW @ 12 tiles | 2022-10-04 | 2 | 2 | 128 | Dell PowerEdge R7515 | AMD EPYC 7763 | Traditional Storage | vCenter 7.0 U1c | VMware ESXi 7.0 U2a | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2022-10-04-dell-poweredge-r7515-serverppkw) |
| [Dell Technologies](https://www.dell.com/) | 18.2000 PPKW @ 16 tiles | 2024-01-23 | 4 | 4 | 256 | Dell PowerEdge C6615 | AMD EPYC 8534P | vSAN Storage | vCenter 8.0 U2a | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-01-23-dell-poweredge-c6615-serverppkw) |

### Server and Storage Power-Performance (11)

| Submitter | Score | Date | Total Hosts | Total Sockets | Total Cores | Server Description | Processor Model | Type of Storage | vCenter Server | Hypervisor | VMmark Version | Primary Storage | Matched Pair | Disclosure |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| [Dell Technologies](https://www.dell.com/) | 39.11 PPKW @ 42 tiles | 2023-10-31 | 4 | 8 | 448 | Dell PowerEdge R760 | Intel Xeon Platinum 8480+ | vSAN Storage | vCenter 8.0 U2 | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2023-10-31-dell-poweredge-r760) |
| [Fujitsu](https://www.fujitsu.com) | 4.1138 PPKW @ 14 tiles | 2021-04-20 | 2 | 4 | 160 | Fujitsu Server PRIMERGY RX2540 M6 | Intel Xeon Platinum 8380 | Traditional Storage | vCenter 7.0 U1 | VMware ESXi 7.0 U2 | 3.1.1 | SCSI Target Server - 5 x RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2021-04-20-fujitsu-primergy-rx2540m6-serverstorageppkw) |
| [Fujitsu](https://www.fujitsu.com) | 2.3881 PPKW @ 1 tile | 2022-05-03 | 2 | 2 | 16 | Fujitsu Server PRIMERGY RX1330 M5 | Intel Xeon E-2388G | Traditional Storage | vCenter 7.0 U2 | VMware ESXi 7.0 U3 | 3.1.1 | SCSI Target Server - Fujitsu Server PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2022-05-03-fujitsu-primergy-rx1330m5-serverstorageppkw) |
| [Dell Technologies](https://www.dell.com/) | 11.0600 PPKW @ 16 tiles | 2024-01-23 | 4 | 4 | 256 | Dell PowerEdge C6615 | AMD EPYC 8534P | vSAN Storage | vCenter 8.0 U2a | VMware ESXi 8.0 U2 | 3.1.1 | VMware vSAN - All Flash |  | [PDF](https://www.vmware.com/docs/2024-01-23-dell-poweredge-c6615-serverstorageppkw) |
| [Fujitsu](https://www.fujitsu.com) | 3.7609 PPKW @ 20 tiles | 2020-10-22 | 2 | 8 | 224 | Fujitsu Server PRIMERGY RX4770 M6 | Intel Xeon Platinum 8380HL | Traditional Storage | vCenter 7.0 U1 | VMware ESXi 7.0 U1 | 3.1.1 | SCSI Target Server - 5 x RX2540 M4; 2 x RX2540 M5 | Yes | [PDF](https://www.vmware.com/docs/2020-10-22-fujitsu-rx4770m6-serverstorageppkw) |
| [Fujitsu](https://www.fujitsu.com) | 3.6750 PPKW @ 8 tiles | 2018-01-16 | 2 | 4 | 112 | Fujitsu Server PRIMERGY RX2540 M4 | Intel Xeon Platinum 8180 | Traditional Storage | vCenter 6.5 | VMware ESXi 6.5 | 3.0 | SCSI Target Server - 3 x Fujitsu Server PRIMERGY RX2540 M2 | Yes | [PDF](https://www.vmware.com/docs/2018-01-16-fujitsu-rx2540m4) |
| [Fujitsu](https://www.fujitsu.com) | 1.9102 PPKW @ 1 tile | 2018-11-06 | 3 | 3 | 18 | Fujitsu Server PRIMERGY RX1330 M4 | Intel Xeon E-2186G | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.5 U2 | 3.0 | SCSI Target Server - 1 x Fujitsu Server PRIMERGY TX2560 M2 |  | [PDF](https://www.vmware.com/docs/2018-11-06-fujitsu-rx1330m4-serverstorageppkw) |
| [Dell Technologies](https://www.dell.com/) | 7.4908 PPKW @ 21 tiles | 2023-03-21 | 2 | 2 | 192 | Dell PowerEdge R7615 | AMD EPYC 9654P | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | FC SAN Storage - Dell PowerMax 8000 | Yes | [PDF](https://www.vmware.com/docs/2023-03-21-dell-poweredge-r7615-serverstorageppkw) |
| [Fujitsu](https://www.fujitsu.com) | 3.5013 PPKW @ 9 tiles | 2019-04-02 | 2 | 4 | 112 | Fujitsu Server PRIMERGY RX2540 M5 | Intel Xeon Platinum 8280 | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 06 | 3.1 | SCSI Target Server - 4 x Fujitsu Server PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2019-04-02-fujitsu-rx2540m5-serverstorageppkw) |
| [Fujitsu](https://www.fujitsu.com) | 2.7464 PPKW @ 1 tile | 2019-11-01 | 2 | 2 | 16 | Fujitsu Server PRIMERGY RX1330 M4 | Intel Xeon E-2288G | Traditional Storage | vCenter 6.7.0d | VMware ESXi 6.7 EP 08 | 3.1 | SCSI Target Server - 1 x Fujitsu Server PRIMERGY RX2540 M4 | Yes | [PDF](https://www.vmware.com/docs/2019-11-01-fujitsu-rx1330m4-serverstorageppkw) |
| [Fujitsu](https://www.fujitsu.com) | 4.8019 PPKW @ 22 tiles | 2023-03-21 | 2 | 4 | 240 | Fujitsu Server PRIMERGY RX2540 M7 | Intel Xeon Platinum 8490H | Traditional Storage | vCenter 8.0 GA | VMware ESXi 8.0 GA | 3.1.1 | SCSI Target Server - 5 x PRIMERGY RX2540 M4; 3 x RX2540 M5 | Yes | [PDF](https://www.vmware.com/docs/2023-03-21-fujitsu-primergy-rx2540m7-serverstorageppkw) |