<?xml-stylesheet type="text/xsl" href="../vi_vsan_profile.xslt"?>
<data>
<lastUpdateDate>October 31, 2023</lastUpdateDate>
<guideName>vSAN Hardware Quick Reference Guide</guideName>
<copyright>Copyright &#xA9; 2010-2017 VMware, Inc. All rights reserved.</copyright>
<searchDocName>Search Results</searchDocName>
<searchDocFullName>vSAN Hardware Quick Reference Guide Search Results</searchDocFullName>
<disclaimer>
<heading><![CDATA[Disclaimer]]></heading>
<description><![CDATA[THIS CONTENT IS PROVIDED AS IS, AND TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, VMWARE DISCLAIMS ALL OTHER REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED, REGARDING THIS CONTENT, INCLUDING THEIR FITNESS FOR A PARTICULAR PURPOSE, THEIR MERCHANTABILITY, OR THEIR NONINFRINGEMENT. VMWARE SHALL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OF THIS CONTENT, INCLUDING DIRECT, INDIRECT, CONSEQUENTIAL DAMAGES, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF VMWARE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

THE VMWARE COMPATIBILITY GUIDE IS UPDATED FROM TIME TO TIME WITHOUT NOTICE.  FOR THE LATEST VMWARE COMPATIBILITY GUIDE, PLEASE GO TO THE FOLLOWING LINK: http://www.vmware.com/resources/compatibility]]></description>
</disclaimer>
<rows>
<row><profiles><profile><name>AF-8 Series</name><numberOfVMs>Up to 120</numberOfVMs><iops>Up to 80K</iops><rawStorageCapacity>12 TB</rawStorageCapacity><cpu>24 core</cpu><memory>384 GB</memory><capacityTier><capacity>12 TB (Minimum 3 drives in each disk group)</capacity><capacity>SSD Endurance Class A or above</capacity><capacity>SSD Performance Class C or above</capacity></capacityTier><cachingTier><cache>2x400 GB</cache><cache>SSD Endurance Class D or above</cache><cache>SSD Performance Class E or above</cache></cachingTier><recommendedCachingTier><recommendedCache>All NVMe</recommendedCache><recommendedCache>NVMe + SAS</recommendedCache></recommendedCachingTier><ioController>Queue Depth >= 512</ioController><nic>10 GbE or more</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>AF-6 Series</name><numberOfVMs>Up to 60</numberOfVMs><iops>Up to 50K</iops><rawStorageCapacity>8 TB</rawStorageCapacity><cpu>24 core</cpu><memory>256 GB</memory><capacityTier><capacity>8 TB (Minimum 3 drives in each disk group)</capacity><capacity>SSD Endurance Class A or above</capacity><capacity>SSD Performance Class C or above</capacity></capacityTier><cachingTier><cache>2x200 GB</cache><cache>SSD Endurance Class C or above</cache><cache>SSD Performance Class D or above</cache></cachingTier><recommendedCachingTier><recommendedCache>All SAS</recommendedCache><recommendedCache>All NVMe</recommendedCache><recommendedCache>NVMe + SATA/SAS</recommendedCache><recommendedCache>SAS + SATA</recommendedCache></recommendedCachingTier><ioController>Queue Depth >=512</ioController><nic>10 GbE or more</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>AF-4 Series</name><numberOfVMs>Up to 30</numberOfVMs><iops>Up to 25K</iops><rawStorageCapacity>4 TB</rawStorageCapacity><cpu>20 core</cpu><memory>128 GB</memory><capacityTier><capacity>4 TB (Minimum 2 drives in each disk group)</capacity><capacity>SSD Endurance Class A or above</capacity><capacity>SSD Performance Class C or above</capacity></capacityTier><cachingTier><cache>1x200 GB</cache><cache>SSD Endurance Class C or above</cache><cache>SSD Performance Class D or above</cache></cachingTier><recommendedCachingTier><recommendedCache>All SATA</recommendedCache><recommendedCache>All SAS</recommendedCache><recommendedCache>All NVMe</recommendedCache><recommendedCache>SAS + SATA</recommendedCache><recommendedCache>NVMe + SATA/SAS</recommendedCache></recommendedCachingTier><ioController>Queue Depth >= 256</ioController><nic>10 GbE or more</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>AMD-HY-8 Series</name><numberOfVMs></numberOfVMs><iops></iops><rawStorageCapacity>12 TB</rawStorageCapacity><cpu>32 core</cpu><memory>384 GB</memory><capacityTier><capacity>12 TB (Minimum 3 drives in each disk group)</capacity><capacity>SAS 10K RPM</capacity></capacityTier><cachingTier><cache>2x400 GB</cache><cache>SSD Endurance Class >=D</cache><cache>SSD Performance Class >=E</cache></cachingTier><recommendedCachingTier></recommendedCachingTier><ioController>Queue Depth >= 512</ioController><nic>10 GbE</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>AMD-HY-6 Series</name><numberOfVMs></numberOfVMs><iops></iops><rawStorageCapacity>8 TB</rawStorageCapacity><cpu>24 core</cpu><memory>256 GB</memory><capacityTier><capacity>8 TB (Minimum 3 drives in each disk group)</capacity><capacity>NL-SAS 7.2K RPM</capacity></capacityTier><cachingTier><cache>2x200 GB</cache><cache>SSD Endurance Class >=C</cache><cache>SSD Performance Class >=D</cache></cachingTier><recommendedCachingTier></recommendedCachingTier><ioController>Queue Depth >= 256</ioController><nic>10 GbE</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>AMD-HY-4 Series</name><numberOfVMs></numberOfVMs><iops></iops><rawStorageCapacity>4 TB</rawStorageCapacity><cpu>16 core</cpu><memory>128 GB</memory><capacityTier><capacity>4 TB (Minimum 2 drives in each disk group)</capacity><capacity>NL-SAS 7.2K RPM</capacity></capacityTier><cachingTier><cache>1x200 GB</cache><cache>SSD Endurance Class >=C</cache><cache>SSD Performance Class >=D</cache></cachingTier><recommendedCachingTier></recommendedCachingTier><ioController>Queue Depth >=256</ioController><nic>10 GbE</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>AMD-HY-2 Series</name><numberOfVMs></numberOfVMs><iops></iops><rawStorageCapacity>2 TB</rawStorageCapacity><cpu>8 core</cpu><memory>32 GB</memory><capacityTier><capacity>2 TB (Minimum 2 drives in each disk group)</capacity><capacity>NL-SAS 7.2K RPM</capacity></capacityTier><cachingTier><cache>1x200 GB</cache><cache>SSD Endurance Class >=B</cache><cache>SSD Performance Class >=B</cache></cachingTier><recommendedCachingTier></recommendedCachingTier><ioController>Queue Depth >=256</ioController><nic>10 GbE</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>AMD-AF-8 Series</name><numberOfVMs></numberOfVMs><iops></iops><rawStorageCapacity>12 TB</rawStorageCapacity><cpu>32 core</cpu><memory>384 GB</memory><capacityTier><capacity>12 TB (Minimum 3 drives in each disk group)</capacity><capacity>SSD Endurance Class A or above</capacity><capacity>SSD Performance Class C or above</capacity></capacityTier><cachingTier><cache>2x400 GB</cache><cache>SSD Endurance Class D or above</cache><cache>SSD Performance Class E or above</cache></cachingTier><recommendedCachingTier><recommendedCache>All NVMe</recommendedCache><recommendedCache>NVMe + SAS</recommendedCache></recommendedCachingTier><ioController>Queue Depth >= 512</ioController><nic>10 GbE or more</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>AMD-AF-6 Series</name><numberOfVMs></numberOfVMs><iops></iops><rawStorageCapacity>8 TB</rawStorageCapacity><cpu>24 core</cpu><memory>256 GB</memory><capacityTier><capacity>8 TB (Minimum 3 drives in each disk group)</capacity><capacity>SSD Endurance Class A or above</capacity><capacity>SSD Performance Class C or above</capacity></capacityTier><cachingTier><cache>2x200 GB</cache><cache>SSD Endurance Class C or above</cache><cache>SSD Performance Class D or above</cache></cachingTier><recommendedCachingTier><recommendedCache>All SAS</recommendedCache><recommendedCache>All NVMe</recommendedCache><recommendedCache>NVMe + SATA/SAS</recommendedCache><recommendedCache>SAS + SATA</recommendedCache></recommendedCachingTier><ioController>Queue Depth >=512</ioController><nic>10 GbE or more</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>AMD-AF-4 Series</name><numberOfVMs></numberOfVMs><iops></iops><rawStorageCapacity>4 TB</rawStorageCapacity><cpu>16 core</cpu><memory>128 GB</memory><capacityTier><capacity>4 TB (Minimum 2 drives in each disk group)</capacity><capacity>SSD Endurance Class A or above</capacity><capacity>SSD Performance Class C or above</capacity></capacityTier><cachingTier><cache>1x200 GB</cache><cache>SSD Endurance Class C or above</cache><cache>SSD Performance Class D or above</cache></cachingTier><recommendedCachingTier><recommendedCache>All SATA</recommendedCache><recommendedCache>All SAS</recommendedCache><recommendedCache>All NVMe</recommendedCache><recommendedCache>SAS + SATA</recommendedCache><recommendedCache>NVMe + SATA/SAS</recommendedCache></recommendedCachingTier><ioController>Queue Depth >= 256</ioController><nic>10 GbE or more</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>HY-8 Series</name><numberOfVMs>Up to 100</numberOfVMs><iops>Up to 40K</iops><rawStorageCapacity>12 TB</rawStorageCapacity><cpu>24 core</cpu><memory>384 GB</memory><capacityTier><capacity>12 TB (Minimum 3 drives in each disk group)</capacity><capacity>SAS 10K RPM</capacity></capacityTier><cachingTier><cache>2x400 GB</cache><cache>SSD Endurance Class >=D</cache><cache>SSD Performance Class >=E</cache></cachingTier><recommendedCachingTier></recommendedCachingTier><ioController>Queue Depth >= 512</ioController><nic>10 GbE</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>HY-6 Series</name><numberOfVMs>Up to 50</numberOfVMs><iops>Up to 20K</iops><rawStorageCapacity>8 TB</rawStorageCapacity><cpu>20 core</cpu><memory>256 GB</memory><capacityTier><capacity>8 TB (Minimum 3 drives in each disk group)</capacity><capacity>NL-SAS 7.2K RPM</capacity></capacityTier><cachingTier><cache>2x200 GB</cache><cache>SSD Endurance Class >=C</cache><cache>SSD Performance Class >=D</cache></cachingTier><recommendedCachingTier></recommendedCachingTier><ioController>Queue Depth >= 256</ioController><nic>10 GbE</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>HY-4 Series</name><numberOfVMs>Up to 30</numberOfVMs><iops>Up to 10K</iops><rawStorageCapacity>4 TB</rawStorageCapacity><cpu>16 core</cpu><memory>128 GB</memory><capacityTier><capacity>4 TB (Minimum 2 drives in each disk group)</capacity><capacity>NL-SAS 7.2K RPM</capacity></capacityTier><cachingTier><cache>1x200 GB</cache><cache>SSD Endurance Class >=C</cache><cache>SSD Performance Class >=D</cache></cachingTier><recommendedCachingTier></recommendedCachingTier><ioController>Queue Depth >=256</ioController><nic>10 GbE</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>HY-2 Series</name><numberOfVMs>Up to 20</numberOfVMs><iops>Up to 4K</iops><rawStorageCapacity>2 TB</rawStorageCapacity><cpu>6 core</cpu><memory>32 GB</memory><capacityTier><capacity>2 TB (Minimum 2 drives in each disk group)</capacity><capacity>NL-SAS 7.2K RPM</capacity></capacityTier><cachingTier><cache>1x200 GB</cache><cache>SSD Endurance Class >=B</cache><cache>SSD Performance Class >=B</cache></cachingTier><recommendedCachingTier></recommendedCachingTier><ioController>Queue Depth >=256</ioController><nic>10 GbE</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>SF-AF</name><numberOfVMs>Up to 12</numberOfVMs><iops>Up to 15K</iops><rawStorageCapacity>0.6 TB</rawStorageCapacity><cpu>6 core</cpu><memory>32 GB</memory><capacityTier><capacity>600 GB (Minimum 1 capacity drive in each disk group)</capacity><capacity>Performance Class C or above</capacity><capacity>Endurance Class A or above</capacity></capacityTier><cachingTier><cache>1x350 GB (Minimum 1 capacity drive in each disk group)</cache><cache>Performance Class C or above</cache><cache>Endurance Class C or above</cache></cachingTier><recommendedCachingTier></recommendedCachingTier><ioController>Queue Depth >= 256</ioController><nic>10 GbE or more</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>*** Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile><profile><name>SF-HY</name><numberOfVMs>Up to 8</numberOfVMs><iops>Up to 2K</iops><rawStorageCapacity>0.6 TB</rawStorageCapacity><cpu>6 core</cpu><memory>32 GB</memory><capacityTier><capacity>600 GB (Minimum 1 capacity drive in each disk group)</capacity><capacity>NL-SAS 7.2KRPM</capacity></capacityTier><cachingTier><cache>1x350 GB (Minimum 1 capacity drive in each disk group)</cache><cache>Performance Class B or above</cache><cache>Endurance Class B or above</cache></cachingTier><recommendedCachingTier></recommendedCachingTier><ioController>Queue Depth >= 256</ioController><nic>10 GbE or more</nic><notes><note>* VM density can vary based on use case</note><note>** Assumes latest generation CPU architecture</note><note>* Pass through mode recommended; additional controller may be required depending on maximum number of drives supported by the controller</note></notes></profile></profiles><sizingAssumptions>
    <sizingAssumption>
        <header>Disk Group Caching Tier to Capacity Tier Ratio</header>
        <contents>
            <content>Disk Group Ratio: 1 SSD, 1 to 7 HDDs</content>
            <content>>=10% anticipated used capacity</content>
            <refLink>
                <content>For all flash caching guideline, refer the blog </content>
                <visibleText>here</visibleText>
                <link>https://blogs.vmware.com/virtualblocks/2017/01/18/designing-vsan-disk-groups-cache-ratio-revisited/</link>
            </refLink>
        </contents>
    </sizingAssumption>
    <sizingAssumption>
        <header>ESXi Boot</header>
        <contents>
 			<refLink>
 				<content>Please follow vSphere boot guidance at </content>
 				<visibleText>https://kb.vmware.com/s/article/85685</visibleText>
 				<link>https://kb.vmware.com/s/article/85685</link>
         	</refLink>
         </contents>
    </sizingAssumption>
    <sizingAssumption>
        <header>Network</header>
        <contents>
            <content>Minimum two server side network adapter uplinks</content>
            <content>(Dual port NIC) recommended for redundancy</content>
        </contents>
    </sizingAssumption>
    <sizingAssumption>
        <header>SAS Expanders</header>
        <contents>
            <content>SAS Expanders are supported only on a per platform basis. Check Ready Node listings for
                support. In absence of SAS expander support for a Ready Node, only 8 drives supported per controller.
                Add an extra controller if >8 drives are required.
            </content>
        </contents>
    </sizingAssumption>
    <sizingAssumption>
        <header>Device Capacity</header>
        <contents>
            <content>The capacity point for caching  and capacity tier is for guidance only. You can choose different capacity points as long as Performance and Endurance classes are met.</content>
        </contents>
    </sizingAssumption>
</sizingAssumptions>
<designConsiderations>
    <designConsideration>
        <header>Controller Queue Depth</header>
        <contents>
            <content>Controller queue depth impacts the rebuild/resync times. A low controller queue depth may impact the availability of your production VMs during rebuild/resync. A minimum queue depth of 256 is required in vSAN. Some profiles require minimum queue depth of 512 as noted above.
            </content>
        </contents>
    </designConsideration>
    <designConsideration>
        <header>Number of disk groups</header>
        <contents>
            <content>The number of disk groups impacts fault isolation as well as rebuild/resync times.</content>
            <content>**Fault isolation: Configuring more than 1 disk group allows better tolerance against SSD failures since data is spread across more disk groups.</content>
            <content>**Rebuild/resync times: Configuring more than 1 disk group allows faster rebuilds/resyncs.</content>
        </contents>
    </designConsideration>
    <designConsideration>
        <header>Number of capacity drives (HDDs in Hybrid config / SSD in All Flash Configs) in a disk group
        </header>
        <contents>
            <content>The number of capacity tier drives in a disk group has an impact of the performance of vSAN. While a single capacity tier drive is the minimum requirement for a disk group, for better performance when there are more VMs, and better handling of rebuild/resync activities, we recommend configuring more than 1 capacity tier drive per caching tier SSD per our guidance above.
            </content>
        </contents>
    </designConsideration>
    <designConsideration>
        <header>Class of SSDs</header>
        <contents>
            <content>The class of SSD you choose has a direct impact on the performance of your overall system.
            </content>
        </contents>
    </designConsideration>
    <designConsideration>
        <header>Balanced vs Unbalanced cluster</header>
        <contents>
            <content>An unbalanced cluster can impact vSAN performance as well as the rebuild/resync times. A balanced cluster delivers more predictable performance even during hardware failures. In addition, performance impact during resync/rebuild is minimal when the cluster is balanced.
            </content>
        </contents>
    </designConsideration>
    <designConsideration>
        <header>1G vs 10G Ethernet</header>
        <contents>
            <content>The choice of 1G vs 10G Ethernet has an impact of the vSAN performance. Both 1G and 10G networks are supported. For larger, higher performing workloads, 10G interconnect is recommended.
            </content>
        </contents>
    </designConsideration>
    <designConsideration>
        <header>De-duplication, Compression and Erasure Coding Considerations
        </header>
        <contents>
            <content>The sizing does not account for De-duplication, Compression and Erasure Coding. Please visit vSAN Sizing Calculator. If you want to size with storage efficiency turned on and then pick the right Ready Node profile.
            </content>
        </contents>
    </designConsideration>
    <designConsideration>
        <header>Device Protocol
        </header>
        <contents>
            <content>The ReadyNode are certified with particular device type (SAS/SATA/NVMe/HDD). You are not allowed to change the device type.
            </content>
        </contents>
    </designConsideration>
</designConsiderations>
<performanceClasses>
    <performanceClass>
        <name>B</name>
        <ssdTiers>
            <ssdTier>
                vSAN Hybrid - Caching
            </ssdTier>
        </ssdTiers>
        <writesPerSecond>5000 - 9999</writesPerSecond>
    </performanceClass>
    <performanceClass>
        <name>C</name>
        <ssdTiers>
            <ssdTier>
                vSAN Hybrid - Caching
            </ssdTier>
            <ssdTier>
                vSAN All Flash - Capacity
            </ssdTier>
        </ssdTiers>
        <writesPerSecond>10000 - 19999</writesPerSecond>
    </performanceClass>
    <performanceClass>
        <name>D</name>
        <ssdTiers>
            <ssdTier>
                vSAN Hybrid - Caching
            </ssdTier>
            <ssdTier>
                vSAN All Flash - Caching for Medium workloads
            </ssdTier>
            <ssdTier>
                vSAN All Flash - Capacity
            </ssdTier>
        </ssdTiers>
        <writesPerSecond>20000 - 29999</writesPerSecond>
    </performanceClass>
    <performanceClass>
        <name>E</name>
        <ssdTiers>
            <ssdTier>
                vSAN Hybrid - Caching
            </ssdTier>
            <ssdTier>
                vSAN All Flash - Caching for Medium workloads
            </ssdTier>
            <ssdTier>
                vSAN All Flash - Capacity
            </ssdTier>
        </ssdTiers>
        <writesPerSecond>30000 - 99999</writesPerSecond>
    </performanceClass>
    <performanceClass>
        <name>F</name>
        <ssdTiers>
            <ssdTier>
                vSAN Hybrid - Caching
            </ssdTier>
            <ssdTier>
                vSAN All Flash - Caching for High workloads
            </ssdTier>
            <ssdTier>
                vSAN All Flash - Capacity
            </ssdTier>
        </ssdTiers>
        <writesPerSecond>100000 - 349999</writesPerSecond>
    </performanceClass>
    <performanceClass>
        <name>G</name>
        <ssdTiers>
            <ssdTier>
                vSAN Hybrid - Caching
            </ssdTier>
            <ssdTier>
                vSAN All Flash - Caching for High workloads
            </ssdTier>
            <ssdTier>
                vSAN All Flash - Capacity
            </ssdTier>
        </ssdTiers>
        <writesPerSecond>350000+</writesPerSecond>
    </performanceClass>
</performanceClasses>
<enduranceClasses>
    <enduranceClass>
        <name>A</name>
        <ssdTier>vSAN All Flash - Capacity</ssdTier>
        <tbWrites>365</tbWrites>
    </enduranceClass>
    <enduranceClass>
        <name>B</name>
        <ssdTier>vSAN Hybrid - Caching</ssdTier>
        <tbWrites>1825</tbWrites>
    </enduranceClass>
    <enduranceClass>
        <name>C</name>
        <ssdTier>vSAN All Flash - Caching for Medium workloads</ssdTier>
        <tbWrites>3650</tbWrites>
    </enduranceClass>
    <enduranceClass>
        <name>D</name>
        <ssdTier>vSAN All Flash - Caching for High workloads</ssdTier>
        <tbWrites>7300</tbWrites>
    </enduranceClass>
</enduranceClasses>
<renameProfiles>
    <renameProfile>
        <oldProfile>Hybrid-Server-Low</oldProfile>
        <newProfile>HY-2 Series</newProfile>
    </renameProfile>
    <renameProfile>
        <oldProfile>New Hybrid Profile</oldProfile>
        <newProfile>HY-4 Series</newProfile>
    </renameProfile>
    <renameProfile>
        <oldProfile>Hybrid-Server-Medium</oldProfile>
        <newProfile>HY-6 Series</newProfile>
    </renameProfile>
    <renameProfile>
        <oldProfile>Hybrid-Server-High</oldProfile>
        <newProfile>HY-8 Series</newProfile>
    </renameProfile>
    <renameProfile>
        <oldProfile>Hybrid-VDI-Linked Clones</oldProfile>
        <newProfile>HY-8 Series</newProfile>
    </renameProfile>
    <renameProfile>
        <oldProfile>Hybrid-VDI-Full Clones</oldProfile>
        <newProfile>HY-8 Series</newProfile>
    </renameProfile>
    <renameProfile>
        <oldProfile>All Flash-Server-Medium</oldProfile>
        <newProfile>AF-6 Series</newProfile>
    </renameProfile>
    <renameProfile>
        <oldProfile>All Flash-Server-High</oldProfile>
        <newProfile>AF-8 Series</newProfile>
    </renameProfile>
    <renameProfile>
        <oldProfile>All Flash-VDI-Linked Clones</oldProfile>
        <newProfile>AF-8 Series</newProfile>
    </renameProfile>
    <renameProfile>
        <oldProfile>All Flash-VDI-Full Clones</oldProfile>
        <newProfile>AF-8 Series</newProfile>
    </renameProfile>
</renameProfiles>
<additionalResources>
    <resource>
        <visibleText>vSAN Ready Node Configurator</visibleText>
        <link>http://vsanreadynode.vmware.com/RN/RN</link>
    </resource>
    <resource>
        <visibleText>vSAN ReadyNode™ Sizer</visibleText>
        <link>https://vsansizer.vmware.com</link>
    </resource>
    <resource>
        <visibleText>HCI Assessment Tool</visibleText>
        <link>https://www.vmware.com/products/hyper-converged-infrastructure/assessment.html</link>
    </resource>
    <resource>
        <visibleText>vSAN Hardware Quick Reference Guide</visibleText>
        <link>./vi_vsan_profile.pdf</link>
    </resource>
</additionalResources>
<rnNotes>
    <note>
        <text>*Memory: Use balanced DIMM population as recommended by OEM partner to avoid any performance penalty(For example: Maintaining 1DIMM-Per-Channel is one of the recommendations)</text>
    </note>
    <note>
        <text>**Queue Depth: Queue Depth of the controller has to be the aggregated Queue Depth of all it's connecting device(same or greater)</text>
    </note>
</rnNotes>
</row></rows>
</data>